40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Feb 23 15:48:43 2017, johannes, Update, Computers, c1psl un-bootable scope_PDA520_ITM_aligned_ETM_misaligned.pngscope_PDA520_ITM_slightly_misaligned.pngpmc_trans_last10days.png
    Reply  Thu Feb 23 18:52:53 2017, rana, Update, Computers, c1psl un-bootable 
       Reply  Thu Feb 23 19:44:48 2017, johannes, Update, Computers, c1psl un-bootable slow_startup_logs.tar.gz
          Reply  Fri Feb 24 20:38:01 2017, johannes, Update, Computers, c1psl boot-stall culprit identified 
          Reply  Tue Feb 28 01:28:52 2017, johannes, Update, Computers, c1psl un-bootable 
             Reply  Wed Mar 8 18:18:51 2017, johannes, Update, Computer Scripts / Programs, loss script 
                Reply  Thu Mar 9 22:28:11 2017, johannes, Update, Computer Scripts / Programs, loss script 
                   Reply  Fri Mar 10 11:37:25 2017, gautam, Update, Computer Scripts / Programs, loss script 
                      Reply  Fri Mar 10 19:48:56 2017, johannes, Update, Computer Scripts / Programs, loss script 
                         Reply  Sat Mar 11 20:11:58 2017, johannes, Update, Computer Scripts / Programs, loss script 
Message ID: 12883     Entry time: Sat Mar 11 20:11:58 2017     In reply to: 12882
Author: johannes 
Type: Update 
Category: Computer Scripts / Programs 
Subject: loss script 

Yarm script running on Pianosa. Still working on visualization of the ETMX lossmap.

Quote:

Loss script running again, on Pianosa this time. Due to an oversight in the code the beam wasn't actually moved across ETMY last night. This time I confirmed that the correct offset value is written as a demodulation parameter to the correct mirror degree of freedom. Script will probably run through the night. Yarm is currently misaligned but previous alignment was saved.

 