40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Wed Jan 25 15:41:29 2017, Lydia, Update, IMC, 29.5 MHz modulation depth measurement plan
|
Wed Jan 25 17:30:03 2017, Koji, Update, IMC, 29.5 MHz modulation depth measurement plan
|
Wed Jan 25 19:39:07 2017, gautam , Update, IMC, 29.5 MHz modulation depth measurement plan
|
Fri Jan 27 21:25:11 2017, Lydia, Update, IMC, 29.5 MHz modulation depth
|
Sat Jan 28 01:25:51 2017, gautam, Update, IMC, 29.5 MHz modulation depth 
|
Mon Jan 30 19:07:48 2017, gautam, Update, IMC, RF AM stabilization box pulled out
|
Tue Jan 31 01:07:20 2017, Lydia, Update, IMC, RF AM stabilization box pulled out
|
Tue Jan 31 13:46:34 2017, rana, Update, IMC, RF AM stabilization box pulled out
|
Tue Jan 31 14:17:48 2017, gautam, Update, IMC, RF AM stabilization box pulled out
|
Tue Jan 31 22:07:13 2017, gautam, Update, IMC, RF AM stabilization box revamp
|
Tue Jan 31 22:28:39 2017, Lydia, Update, IMC, RF AM stabilization box pulled out
|
Wed Feb 1 11:51:19 2017, Koji, Update, IMC, RF AM stabilization box pulled out
|
Wed Feb 1 16:45:56 2017, Lydia, Update, IMC, RF AM stabilizer box Modification Plan
|
Wed Feb 1 20:49:34 2017, rana, Update, IMC, RF AM stabilizer box Modification Plan
|
Wed Feb 1 23:13:30 2017, Lydia, Update, IMC, RF AM stabilizer box Modification Plan
|
Sun Feb 5 21:56:50 2017, Lydia, Update, IMC, 29.5 MHz stabilizer box replacement
|
Tue Feb 7 12:01:10 2017, Lydia, Update, IMC, 29.5 MHz stabilizer box replacement
|
Tue Feb 7 17:00:55 2017, Lydia, Update, IMC, 29.5 MHz stabilizer box replacement
|
Fri Feb 10 02:14:10 2017, gautam, Update, IMC, 29.5 MHz stabilizer box replacement
|
Fri Feb 10 11:41:43 2017, Lydia, Update, IMC, 29.5 MHz stabilizer box replacement
|
Fri Feb 10 13:24:28 2017, rana, Update, IMC, 29.5 MHz stabilizer box replacement
|
Fri Feb 10 18:21:21 2017, gautam, Update, IMC, IMC Demod board
|
Fri Feb 10 19:32:15 2017, Koji, Update, IMC, IMC Demod board
|
Sun Feb 12 01:16:57 2017, gautam, Update, IMC, IMC length loop - summary of changes    
|
Mon Feb 13 11:55:14 2017, rana, Update, IMC, IMC length loop - summary of changes
|
Mon Feb 13 13:34:44 2017, gautam, Update, IMC, IMC length loop - bad SMA cable replaced
|
Mon Feb 13 19:44:55 2017, Lydia, Update, IMC, Front panel for 29.5 MHz amplifier box
|
Wed Mar 1 21:15:40 2017, Lydia, Update, IMC, Front panel for 29.5 MHz amplifier box
|
Wed Mar 1 23:56:09 2017, gautam, Update, IMC, Front panel for 29.5 MHz amplifier box
|
Thu Mar 2 20:32:18 2017, Lydia, Update, IMC, Front panel for 29.5 MHz amplifier box
|
Wed Feb 15 23:54:13 2017, gautam, Update, IMC, IMC saga continues... 
|
Fri Feb 17 20:10:18 2017, gautam, Update, IMC, WFS servos turned back on
|
Sat Feb 18 14:09:06 2017, rana, Update, IMC, WFS servos turned back on
|
Sat Feb 18 21:50:48 2017, gautam, Update, IMC, WFS servos turned back on
|
Sun Mar 5 12:41:23 2017, gautam, Update, IMC, WFS servo-steppin  
|
|
Message ID: 12816
Entry time: Fri Feb 10 02:14:10 2017
In reply to: 12809
Reply to this: 12817
|
Author: |
gautam |
Type: |
Update |
Category: |
IMC |
Subject: |
29.5 MHz stabilizer box replacement |
|
|
Lydia finished up installing the new RF amplifier, and will elog the details of the installation.
I wanted to try and measure the IMC OLG to compare against my Simulink model. So I went about performing a few checks. Summary of my findings:
- The amplifier seems to be working fine. I checked powers at the input, output to EOM and output to distribution box (that serves the various LOs) first with a 30dB attenuator at the input, and subsequently with the design choice of 5dB attenuator at the input. Everything seemed in order.
- I installed a 30 dB attenuator at the MC REFL PD input to the demod board since my (rough) calculations suggested that our modifications would have resulted in the RF beat power between carrier and sideband increasing in power by ~27dB.
- I then opened the PSL shutter and tried locking the IMC - with manual tweaking of the various gains, I was able to lock.
- But getting to this point took me a while so I couldn't get an OLG measurement in.
TBC tomorrow, I'm leaving the PSL shutter closed and the RF source off for tonight... |