40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Thu Nov 17 15:17:16 2016, gautam, Update, IMC, MCL Feedback  
|
Wed Nov 23 01:13:02 2016, gautam, Update, IMC, MCL Feedback   
|
Wed Nov 23 15:08:56 2016, rana, Update, IMC, MCL Feedback
|
Fri Feb 3 00:36:52 2017, gautam, Update, IMC, MCL Feedback - framing the problem
|
Fri Feb 3 11:40:09 2017, rana, Update, IMC, MCL Feedback - framing the problem
|
Mon Feb 6 17:03:41 2017, gautam, Update, IMC, MCL Feedback - simulink model updated
|
Mon Feb 6 18:20:08 2017, Koji, Update, IMC, MCL Feedback - simulink model updated
|
Wed Feb 8 19:13:02 2017, gautam, Update, IMC, MCL Feedback - TF measurements
|
Thu Feb 9 23:35:34 2017, gautam, Update, IMC, MCL Feedback - TF measurements    
|
|
Message ID: 12804
Entry time: Mon Feb 6 17:03:41 2017
In reply to: 12795
Reply to this: 12805
|
Author: |
gautam |
Type: |
Update |
Category: |
IMC |
Subject: |
MCL Feedback - simulink model updated |
|
|
I've edited Rana's Simulink model to reflect the current IMC servo topology (to the best of my understanding). I've tried to use Transfer Function blocks wherever possible so that we can just put in the appropriate zpk model in the script that will linearize the whole loop. I've also omitted the FSS SLOW loop for now.
I've been looking through some old elogs and it looks like there have been several modifications to both the MC servo board (D040180) and the TT FSS Box (D040105). I think it is easiest just to measure these TFs since the IMC is still down, so I will set about doing that today. There is also a Pomona Box between the broadband EOM and the output of the TT FSS box, which is meant to sum in the modulation for PMC locking, about which I have not yet found anything on the elog.
So the next steps are:
- Measure/estimate all the unknown TFs and gains in this schematic
- Linearize the model, get the OLG, see if the model matches previously measured OLGs (with the MCL part disabled)
- Once the model is verified to be correct, look at couplings of various noise sources in the MCL part of the loop, and come up with a suitable controller.
If anyone sees something wrong with this topology, please let me know so that I can make the required changes.

|
|
|