Entry  Thu Dec 29 21:48:32 2016, rana, Update, IOO, MC AutoLocker hung because c1iool0 asleep again 
    Reply  Fri Feb 10 13:04:32 2017, rana, Update, IOO, MC AutoLocker hung because c1iool0 asleep again 
Message ID: 12691     Entry time: Thu Dec 29 21:48:32 2016     Reply to this: 12818
Author: rana 
Type: Update 
Category: IOO 
Subject: MC AutoLocker hung because c1iool0 asleep again 

MC unlocked, Autolocker waiting for c1iool0 EPICS channels to respond. c1iool0 was responding to ping, but not to telnet. Keyed the crate and its coming back now.

There's many mentions of c1iool0 in the recent past, so it seems like its demise must be imminent. Good thing we have an Acromag team on top of things!

Also, the beam on WFS2 is too high and the autolocker is tickling the Input switch on the servo board too much: this is redundant / conflicting with the MC2 tickler.