Mon Dec 19 22:05:09 2016, Koji, Summary, IOO, PMC, IMC aligned. The ringdown PD/Lens removed.
|
Wed Dec 21 21:03:06 2016, Koji, Summary, IOO, IMC WFS tuning
|
Thu Dec 22 18:39:09 2016, Koji, Summary, IOO, IMC WFS tuning 
|
Fri Dec 23 20:53:44 2016, Koji, Summary, IOO, IMC WFS tuning 
|
Fri Dec 23 21:05:56 2016, Koji, Summary, IOO, IMC WFS tuning    
|
Sun Dec 25 14:39:59 2016, Koji, Summary, IOO, IMC WFS tuning
|
Mon Dec 26 12:45:31 2016, Koji, Summary, IOO, IMC WFS tuning 
|
Thu Dec 29 13:22:21 2016, rana, Summary, IOO, IMC WFS tuning
|
Thu Dec 29 16:52:51 2016, Koji, Summary, IOO, IMC WFS tuning
|
Thu Dec 29 21:35:30 2016, rana, Summary, IOO, IMC WFS tuning
|
Tue Jan 24 01:04:16 2017, gautam, Summary, IOO, IMC WFS RF power levels
|
Fri Jan 27 00:14:02 2017, gautam, Summary, IOO, IMC WFS RF power levels
|
|
Message ID: 12690
Entry time: Thu Dec 29 21:35:30 2016
In reply to: 12689
Reply to this: 12748
|
Author: |
rana |
Type: |
Summary |
Category: |
IOO |
Subject: |
IMC WFS tuning |
|
|
The WFS gains are supposedly maximized already. If we remotely try to increase the gain, the two MAX4106 chips in the RF path will oscillate with each other.
We should insert a bi-directional coupler (if we can find some LEMO to SMA converters) and find out how much actual RF is getting into the demod board. |
|
|