40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sat Nov 12 01:09:56 2016, gautam, Update, LSC, Recovering DRMI locking 
    Reply  Wed Nov 16 03:10:01 2016, gautam, Update, LSC, DRMI locked on 1f and 3f signals 
       Reply  Wed Nov 16 08:14:43 2016, Steve, Update, LSC, DRMI locked on 1f and 3f signals 5hrs.png
       Reply  Mon Nov 21 14:02:32 2016, gautam, Update, LSC, DRMI locked on 3f signals, arms held on ALS DRMIArms_Nov20.pdf
    Reply  Wed Nov 23 16:21:02 2016, gautam, Update, LSC, ITMY UL glitches are back ITMYproblemsBack.png
       Reply  Mon Nov 28 10:27:13 2016, gautam, Update, SUS, ITMY UL glitches are back ITMY_satboxSpectra.pdfITMY_UL_testerBox.png
       Reply  Tue Nov 29 11:07:37 2016, Steve, Update, LSC, ITMY UL glitches are back gliching400d.png
          Reply  Wed Nov 30 01:47:56 2016, gautam, Update, LSC, Suspension woes IMCwoes.png
             Reply  Wed Nov 30 17:08:56 2016, gautam, Update, LSC, Binary output breakout box removed 
                Reply  Thu Dec 1 02:19:13 2016, gautam, Update, LSC, Binary output breakout box restored MC1_glitch_fast.pngITMY_testerGlitch.pngITMYsatbox.pngULcomparison.pdf
                   Reply  Thu Dec 1 08:02:57 2016, Steve, Update, LSC, glitching ITMY_UL_LL ITMY_UL_LL.png
                      Reply  Fri Dec 2 11:56:42 2016, gautam, Update, LSC, MC1 LEMO jiggled IMG_3474.JPGMC1_LR_dead.png
                         Reply  Mon Dec 5 15:05:37 2016, gautam, Update, LSC, MC1 glitches are back Mc1glitches.png
                      Reply  Thu Dec 8 10:13:43 2016, Steve, Update, LSC, glitching ITMY_UL has a history glitching__ITMY-UL_2007.png
Message ID: 12652     Entry time: Wed Nov 30 17:08:56 2016     In reply to: 12648     Reply to this: 12653
Author: gautam 
Type: Update 
Category: LSC 
Subject: Binary output breakout box removed 

[ericq, gautam]

To diagnose the glitches in OSEM readouts, we have removed one of the PCIE BO D37 to IDE50 adaptor boxes from 1X5. All the watchdogs were turned off, and the power to the unit was cut before the cables on the front panel were removed. I am working on the diagnosis, I will update more later in the evening. Note that according to the c1sus model, the box we removed supplies backplane logic inputs that control whitening for ITMX, ITMY, BS and PRM (in case anyone is wondering/needs to restore damping to any of these optics). The whitening settings for the IMC mirrors resides on the other unit in 1X5, and should not be affected.