40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sat Nov 12 01:09:56 2016, gautam, Update, LSC, Recovering DRMI locking 
    Reply  Wed Nov 16 03:10:01 2016, gautam, Update, LSC, DRMI locked on 1f and 3f signals 
       Reply  Wed Nov 16 08:14:43 2016, Steve, Update, LSC, DRMI locked on 1f and 3f signals 5hrs.png
       Reply  Mon Nov 21 14:02:32 2016, gautam, Update, LSC, DRMI locked on 3f signals, arms held on ALS DRMIArms_Nov20.pdf
    Reply  Wed Nov 23 16:21:02 2016, gautam, Update, LSC, ITMY UL glitches are back ITMYproblemsBack.png
       Reply  Mon Nov 28 10:27:13 2016, gautam, Update, SUS, ITMY UL glitches are back ITMY_satboxSpectra.pdfITMY_UL_testerBox.png
       Reply  Tue Nov 29 11:07:37 2016, Steve, Update, LSC, ITMY UL glitches are back gliching400d.png
          Reply  Wed Nov 30 01:47:56 2016, gautam, Update, LSC, Suspension woes IMCwoes.png
             Reply  Wed Nov 30 17:08:56 2016, gautam, Update, LSC, Binary output breakout box removed 
                Reply  Thu Dec 1 02:19:13 2016, gautam, Update, LSC, Binary output breakout box restored MC1_glitch_fast.pngITMY_testerGlitch.pngITMYsatbox.pngULcomparison.pdf
                   Reply  Thu Dec 1 08:02:57 2016, Steve, Update, LSC, glitching ITMY_UL_LL ITMY_UL_LL.png
                      Reply  Fri Dec 2 11:56:42 2016, gautam, Update, LSC, MC1 LEMO jiggled IMG_3474.JPGMC1_LR_dead.png
                         Reply  Mon Dec 5 15:05:37 2016, gautam, Update, LSC, MC1 glitches are back Mc1glitches.png
                      Reply  Thu Dec 8 10:13:43 2016, Steve, Update, LSC, glitching ITMY_UL has a history glitching__ITMY-UL_2007.png
Message ID: 12644     Entry time: Tue Nov 29 11:07:37 2016     In reply to: 12638     Reply to this: 12648
Author: Steve 
Type: Update 
Category: LSC 
Subject: ITMY UL glitches are back 

400 days plot. Satelite amp ITMY has been swapped with ETMY

Unlabeled sat.amps are labeled. This plot only makes sense if you know the Cuh-Razy sat amp locations.

Attachment 1: gliching400d.png  44 kB  | Show | Show all
ELOG V3.1.3-