Message ID: 12508     Entry time: Tue Sep 20 10:45:06 2016     In reply to: 12507     Reply to this: 12510
Author: rana 
Type: Update 
Category: General 
Subject: Further recovery progress 

Rana suspicious. We had arms locked before pumpdown with beams on Transmon PDs. If they're off now, must be beams are far off on the mirrors. Try A2L to estimate spot positions before walkin the beams too far.