40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Jul 5 14:12:56 2016, varun, Update, Electronics, Antialiasing Filter Update AA.pdfAAtop.pdfAAbottom.pdfAAbrd.pdfAA.zip
    Reply  Sun Jul 10 18:20:39 2016, rana, Update, Electronics, Antialiasing Filter Update 
Message ID: 12242     Entry time: Tue Jul 5 14:12:56 2016     Reply to this: 12286
Author: varun 
Type: Update 
Category: Electronics 
Subject: Antialiasing Filter Update 

I am trying to design an antialiasing filter, which also has two switchable whitening stages. I have designed a first version of a PCB for this.

The board takes differential input through PCB mountable BNCs. It consists of an instrumentaiton amplifier made using quad opamp ADA4004, followed by two whitening blocks, also made using ADA4004, which can be bypassed if needed, depending upon a control input. The mux used for this purpose is Maxim MAX4158EUA. These two whitening blocks are followed by 2 the LPF stages. A third LPF stage could be added if needed. These use AD829 opamps. After the LPFs are two amplifiers for giving a differential output through two output BNCs. The schematic is shown in attachment 1: "AA.pdf". The top layers of the layout are shown in attachment 2 (AAtop.pdf), the bottom layers in attachment 3 (AAbottom.pdf), and the entire layout in attachment 4 (AAbrd.pdf). 

The board has 6 layers (in the order from top to bottom):

1) Top signal layer; 

2) Internal plane 1 (GND),

3) Internal plane 2 (+15V),

4) Internal plane 3 (-15V),

5) Internal plane 4 (GND),

6) Bottom signal layer. 

Power: +15, -15 and GND is given through a 4 pin header connector. 

The dimensions of the board are 1550 mil \times 6115 mil (38.1mm\times155.3mm) and the overall dimensions including the protruding BNC edges are 1550 mil \times 7675 mil (38.1mm\times194.9mm)

I would like to have inputs on the layout telling me if any component/trace needs to be changed/better placed, any other things about the board need to be changed, etc.

 

P.S.: I have also added a zipped folder "AA.zip" containing the schematic and board files, as well as the above pdfs.

Attachment 1: AA.pdf  315 kB  | Show | Hide all | Show all
Attachment 2: AAtop.pdf  266 kB  | Show | Hide all | Show all
Attachment 3: AAbottom.pdf  257 kB  | Hide | Hide all | Show all
AAbottom.pdf
Attachment 4: AAbrd.pdf  289 kB  | Show | Hide all | Show all
Attachment 5: AA.zip  9.310 MB
ELOG V3.1.3-