Entry  Wed Jun 8 13:50:39 2016, jamie, Configuration, CDS, Spectracom IRIG-B card installed on fb1 
    Reply  Thu Jun 9 13:28:07 2016, jamie, Configuration, CDS, Spectracom IRIG-B card installed on fb1 
       Reply  Fri Jun 10 12:09:01 2016, jamie, Configuration, CDS, IRIG-B debugging 
          Reply  Fri Jun 10 12:21:54 2016, jamie, Configuration, CDS, GPS receiver not resetting properly 
             Reply  Mon Jun 20 11:11:20 2016, Steve, Configuration, CDS, GPS receiver not resetting properly 
                Reply  Mon Jun 20 11:19:41 2016, jamie, Configuration, CDS, GPS receiver not resetting properly 
                   Reply  Mon Jun 20 14:03:04 2016, jamie, Configuration, CDS, EndRun GPS receiver upgraded, fixed GPSreceiverWorking.jpg
          Reply  Wed Jun 15 10:19:10 2016, Steve, Configuration, CDS, GPS antennas... debugging 6x
Message ID: 12202     Entry time: Mon Jun 20 14:03:04 2016     In reply to: 12201
Author: jamie 
Type: Configuration 
Category: CDS 
Subject: EndRun GPS receiver upgraded, fixed 

I just upgraded the EndRun Technologies Tempus LX GPS receiver timing unit, and it seems to have fixed all the problems.  cool

Thanks to Steve for getting the info from EndRun.  There was indeed a bug in the firmware that was fixed with a firmware upgrade.

I upgraded both the system firmware and the firmware of the GPS subsystem:

Tempus LX GPS(root@Tempus:~)-> gntpversion 
Tempus LX GPS 6010-0044-000 v 5.70 - Wed Oct 1 04:28:34 UTC 2014
Tempus LX GPS(root@Tempus:~)-> gpsversion 
F/W 5.10 FPGA 0416
Tempus LX GPS(root@Tempus:~)->

After reboot the system is fully functional, displaying the correct time, and outputting the correct IRIG-B data, as confirmed by the VME timing unit.

I added a wiki page for the unit: https://wiki-40m.ligo.caltech.edu/NTP

 

Steve added this picture

Attachment 1: GPSreceiverWorking.jpg  1.082 MB  Uploaded Mon Jun 20 17:32:08 2016  | Hide | Hide all
GPSreceiverWorking.jpg
ELOG V3.1.3-