Entry  Wed Jun 8 13:50:39 2016, jamie, Configuration, CDS, Spectracom IRIG-B card installed on fb1 
    Reply  Thu Jun 9 13:28:07 2016, jamie, Configuration, CDS, Spectracom IRIG-B card installed on fb1 
       Reply  Fri Jun 10 12:09:01 2016, jamie, Configuration, CDS, IRIG-B debugging 
          Reply  Fri Jun 10 12:21:54 2016, jamie, Configuration, CDS, GPS receiver not resetting properly 
             Reply  Mon Jun 20 11:11:20 2016, Steve, Configuration, CDS, GPS receiver not resetting properly 
                Reply  Mon Jun 20 11:19:41 2016, jamie, Configuration, CDS, GPS receiver not resetting properly 
                   Reply  Mon Jun 20 14:03:04 2016, jamie, Configuration, CDS, EndRun GPS receiver upgraded, fixed GPSreceiverWorking.jpg
          Reply  Wed Jun 15 10:19:10 2016, Steve, Configuration, CDS, GPS antennas... debugging 6x
Message ID: 12161     Entry time: Thu Jun 9 13:28:07 2016     In reply to: 12158     Reply to this: 12166
Author: jamie 
Type: Configuration 
Category: CDS 
Subject: Spectracom IRIG-B card installed on fb1 

Something is wrong with the timing we're getting out of the symmetricom driver, associated with the new spectracom card.

controls@fb1:~/rtscore/tests/advLigoRTS-40m/src/drv/symmetricom 127$ lalapps_tconvert 
1149538884
controls@fb1:~/rtscore/tests/advLigoRTS-40m/src/drv/symmetricom 0$ cat /proc/gps 
704637380.00
controls@fb1:~/rtscore/tests/advLigoRTS-40m/src/drv/symmetricom 0$ 

The GPS time is way off, and it's counting up at something like 900 seconds/second.  Something is misconfigured, but I haven't figured out what yet.

The timing distribution module we're using is spitting out what appears to be an IRIG B122 signal (amplitude moduled 1 kHz carrier), which I think is what we expect.  This is being fed into the "AM IRIG input" connector on the card.

Not sure why the driver is spinning so fast, though, with the wrong baseline time.  Reboot of the machine didn't help.