40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Oct 19 11:20:34 2015, gautam, Update, VAC, RGA scan reset RGAscan_151019.png
    Reply  Thu Apr 21 15:12:38 2016, Steve, Update, VAC, RGA is not working 
       Reply  Wed May 11 16:39:01 2016, ericq, Update, VAC, c0rga alive, output wonky 
          Reply  Thu May 12 14:29:58 2016, gautam, Update, VAC, RGA back up and running RGAscan_12May2016.png
             Reply  Tue May 17 14:46:51 2016, Steve, Update, VAC, RGA scan at day 595 RGAscan595d.pngpd78-560Hz-d600.png
                Reply  Mon Aug 21 14:53:32 2017, gautam, Update, VAC, RGA reset 
Message ID: 12116     Entry time: Thu May 12 14:29:58 2016     In reply to: 12115     Reply to this: 12119
Author: gautam 
Type: Update 
Category: VAC 
Subject: RGA back up and running 

It looks like the hardware reset did the trick. Previously, I had just tried ssh-ing into c0rga and rebooting it. At the time, however, Steve and I noticed that the various LEDs on the RGA unit weren't on, as they are supposed to be in the nominal operating state. Today, Steve reported that all LEDs except the RS232 one were on today, so I just tried following the steps in this elog again, looks like things are back up and running. I'm attaching a plot of the scan generated using plotrgascan MATLAB script, it looks comparable to the plot in elog 11697, which if I remember right, was acceptable.

Unless there is some reason we want to keep this c0rga machine, I will recommission one of the spare Raspberry Pis lying around to interface with the RGA scanner when I get the time...

Quote:
Quote:

Our last RGA scan is from February 14, 2016  We had a power outage on the 15th

Gautom has not succeded  reseting it. The old c0rga computer looks dead. Q may resurrect it, if he can?

The c0rga computer was off, I turned it on via front panel button. After running RGAset.py, RGAlogger.py seems to run. However, there are error messages in the output of the plotrgascan MATLAB script; evidiently there are some negative/bogus values in the output. 

I'll look into it more tomorrow.

This is a cold scan.

Attachment 1: RGAscan_12May2016.png  28 kB  | Hide | Hide all
RGAscan_12May2016.png
ELOG V3.1.3-