Fri Jan 22 11:33:20 2016, gautam, Update, Green Locking, AUX-X AM/PM investigations  
|
Fri Jan 22 13:33:37 2016, ericq, Update, Green Locking, AUX-X AM/PM investigations
|
Fri Jan 22 17:22:06 2016, gautam, Update, Green Locking, AUX-X AM/PM investigations 
|
Fri Jan 22 18:46:03 2016, rana, Update, Green Locking, AUX-X AM/PM investigations
|
|
Message ID: 11945
Entry time: Fri Jan 22 13:33:37 2016
In reply to: 11944
Reply to this: 11946
|
Author: |
ericq |
Type: |
Update |
Category: |
Green Locking |
Subject: |
AUX-X AM/PM investigations |
|
|
Quote: |
Attachment #1 shows the measured AM response. It differs qualitatively in shape from the earlier measurements reported in this elog and on the wiki below the 100kHz region.
|
It looks like some of the features may have shifted in frequency. The previous measurement results can be found in /users/OLD/mott/PZT/2NPRO , can you plot the two AM measurements together? |