40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Sat Nov 21 00:45:30 2015, Koji, Update, IOO, IMC fix   
|
Sat Nov 21 00:46:33 2015, Koji, Update, IOO, IMC OLTF 
|
Sun Nov 22 12:12:17 2015, Koji, Update, IOO, IMC OLTF
|
Sun Nov 22 07:09:01 2015, rana, Update, IOO, IMC fix
|
Sun Nov 22 12:07:09 2015, Koji, Update, IOO, IMC fix
|
Mon Nov 23 22:12:10 2015, Koji, Update, IOO, LO level check for the IMC demod board 
|
Wed Nov 25 04:24:21 2015, rana, Update, IOO, LO level check for the IMC demod board
|
Wed Nov 25 10:07:10 2015, Koji, Update, IOO, LO level check for the IMC demod board
|
Wed Nov 25 16:46:10 2015, Koji, Update, IOO, LO level check for the IMC demod board
|
Wed Nov 25 20:07:35 2015, rana, Update, IOO, LO level check for the IMC demod board
|
Mon Nov 30 14:12:14 2015, ericq, Update, LSC, LO level check for the LSC RF distribution box
|
Mon Nov 30 15:17:57 2015, Koji, Update, LSC, LO level check for the LSC RF distribution box
|
|
Message ID: 11811
Entry time: Wed Nov 25 16:46:10 2015
In reply to: 11808
Reply to this: 11812
|
Author: |
Koji |
Type: |
Update |
Category: |
IOO |
Subject: |
LO level check for the IMC demod board |
|
|
Awwww. I found that the demod board has the power splitter (PSCJ-2-1) with one output unterminated.
This power splitter should be removed.
https://dcc.ligo.org/D1500443 |
|
|