40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sat Nov 21 00:45:30 2015, Koji, Update, IOO, IMC fix PDRFsignal_cable.JPGQsignal_cable1.JPGQsignal_cable2.JPGQsignal_cable3.JPG
    Reply  Sat Nov 21 00:46:33 2015, Koji, Update, IOO, IMC OLTF IMC_OLTF.pdfPMC_noise_comparison.pdf
       Reply  Sun Nov 22 12:12:17 2015, Koji, Update, IOO, IMC OLTF 
    Reply  Sun Nov 22 07:09:01 2015, rana, Update, IOO, IMC fix 
       Reply  Sun Nov 22 12:07:09 2015, Koji, Update, IOO, IMC fix 
          Reply  Mon Nov 23 22:12:10 2015, Koji, Update, IOO, LO level check for the IMC demod board IMG_2137.JPGIMG_2138.JPG
             Reply  Wed Nov 25 04:24:21 2015, rana, Update, IOO, LO level check for the IMC demod board 
                Reply  Wed Nov 25 10:07:10 2015, Koji, Update, IOO, LO level check for the IMC demod board 
                   Reply  Wed Nov 25 16:46:10 2015, Koji, Update, IOO, LO level check for the IMC demod board D990511-40m_151123.pdf
                      Reply  Wed Nov 25 20:07:35 2015, rana, Update, IOO, LO level check for the IMC demod board 
                   Reply  Mon Nov 30 14:12:14 2015, ericq, Update, LSC, LO level check for the LSC RF distribution box 
                      Reply  Mon Nov 30 15:17:57 2015, Koji, Update, LSC, LO level check for the LSC RF distribution box 
Message ID: 11808     Entry time: Wed Nov 25 10:07:10 2015     In reply to: 11807     Reply to this: 11811   11825
Author: Koji 
Type: Update 
Category: IOO 
Subject: LO level check for the IMC demod board 

I didn't finish making the DCC entry for this module yet.

But the attenuators are
- AT1: 10dB. There is a sign that it was 3dB before ---  a 3dB chip was also attached on the boardnext to 10dB.
- AT2/3: Removed. They were replaced with 0Ohm resistors.

Currently the input is -8dBm. The input and output of the first ERA-5 are -17dBm and +7dBm, respectively.
Then the input and output of the second ERA-5 are -2dBm and 17dB, respectively.

In order to remove the second amplification stage, the first stage has to produce 26dBm. This is too much for either ERA-5 or any chips that fits on the foot print. If we use low gain but high output amp like GVA-81 (G=10dB, DF782 package), it is doable

Input 0dBm - [ATTN 3] - -3dBm - [ERA-5 G=20dB] - +16~+17dBm - [Circuits -9dB] - +7dBm - [Attn 0dB] - +7dBm - [GVA-81 G=10dB] - +17dBm

I think we should check the conditions of all the LSC demods.