I got Steve to get us a new Myrinet fiber network adapter card for fb1:
I just finished installing the card in fb1, and it came up fine. We happened to have a spare fiber, and a spare fiber jack in the DAQ switch, so I went ahead and plugged it in in parallel to the old fb:
controls@fb1:~/rtbuild/trunk 130$ /opt/mx/bin/mx_info
MX Version: 1.2.16
MX Build: controls@fb1:/opt/src/mx-1.2.16 Fri Sep 18 18:32:59 PDT 2015
1 Myrinet board installed.
The MX driver is configured to support a maximum of:
8 endpoints per NIC, 1024 NICs on the network, 32 NICs per host
===================================================================
Instance #0: 364.4 MHz LANai, PCI-E x8, 2 MB SRAM, on NUMA node 0
Status: Running, P0: Link Up
Network: Ethernet 10G
MAC Address: 00:60:dd:43:74:62
Product code: 10G-PCIE-8B-S
Part number: 09-04228
Serial number: 485052
Mapper: 00:60:dd:46:ea:ec, version = 0x00000000, configured
Mapped hosts: 7
ROUTE COUNT
INDEX MAC ADDRESS HOST NAME P0
----- ----------- --------- ---
0) 00:60:dd:43:74:62 fb1:0 1,0
1) 00:25:90:0d:75:bb c1sus:0 1,0
2) 00:30:48:be:11:5d c1iscex:0 1,0
3) 00:30:48:d6:11:17 c1iscey:0 1,0
4) 00:30:48:bf:69:4f c1lsc:0 1,0
5) 00:14:4f:40:64:25 c1ioo:0 1,0
6) 00:60:dd:46:ea:ec fb:0 1,0
We can now work on fb1 while fb continues to run and collect data from the front ends.
I'm still not getting the mx_stream connections to the new fb1 daq to work. I'm leaving everything running as is on fb for the moment. |