40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sat May 16 21:05:24 2015, rana, Update, General, some status 48.png39.png
    Reply  Mon May 18 09:50:00 2015, ericq, Update, General, some status 
       Reply  Mon May 18 11:59:07 2015, rana, Update, General, some status 
          Reply  Tue May 19 16:18:57 2015, ericq, Update, General, crons fixed 
    Reply  Mon May 18 16:28:18 2015, ericq, Update, General, some status 
       Reply  Mon May 18 18:03:12 2015, rana, Update, General, some status CPUtrend.png
          Reply  Tue May 19 00:19:23 2015, rana, Update, General, some status Screen_Shot_2015-05-19_at_12.17.39_AM.png
             Reply  Wed May 20 03:08:27 2015, rana, Update, General, some status 
    Reply  Mon May 18 17:42:14 2015, rana, ericQ, Update, General, some status 
       Reply  Tue May 19 18:55:12 2015, rana, ericQ, Update, General, some status 
          Reply  Wed May 20 11:41:59 2015, ericq, Update, General, some status 
    Reply  Mon Sep 21 00:51:36 2015, rana, Update, General, op340m, autoburt cron =? megatron 
       Reply  Mon Sep 21 11:40:30 2015, ericq, Update, General, Megatron maitenence 
          Reply  Tue Dec 1 17:26:14 2015, Koji, Update, General, Megatron maitenence 
             Reply  Tue Dec 1 20:20:16 2015, Koji, Update, General, Megatron maitenence 
Message ID: 11624     Entry time: Mon Sep 21 00:51:36 2015     In reply to: 11294     Reply to this: 11626
Author: rana 
Type: Update 
Category: General 
Subject: op340m, autoburt cron =? megatron 

I modified the perl script which does our hourly autoburt so that it can run on megatron instead of op340m (old Solaris machine). Nothing major, just some path stuff. That was the last function of op340m that I know of, so after a week of watching this we ought to be able to power it off and send it to e-waste.

Seems to work so far. It complains about some models that aren't running but mostly it reports successful snapshot taking based on the .req files.

Unfortunately, it seems that its only doing the new target directory, so its missing all of our old VME machines which still use the /cvs/cds/caltech/target area.

But I think Gautam and Jamie and Aidan have volunteered to start our slow controls upgrade by moving the EX slow controls to Acromag and into the new target area. We ought to modify the CRON to point at the old directory for now, but its a temporary fix hopefully.