Message ID: 11585
Entry time: Wed Sep 9 11:33:58 2015
In reply to: 11474
|
Author: |
rana |
Type: |
Update |
Category: |
Summary Pages |
Subject: |
Summary Page updates |
|
|
- Made most plots in IOO tab only plot when MC_TRANS > 10000 using Eve's MC_LOCK state definition.
- added the 0.03 - 0.1 Hz and 10-30 Hz bands to the PEM SEIS BLRMS tab and set the y-scales to the same as SeismicRainbowSTS.stp
- set state PMC_LOCK in PSL tab and made some of those plots only plot when PMC trans > 0.6.
- SUS-OL page showed me that the ETM yaw spectrum was wacky, which lead me to find that it was completely uncentered. Stop leaving the room lights ON Steve!!
I also set the quadrant offsets by blocking the QPD with a piece of metal (teflon doesn't work).
- set c1summary to only plot some when X or Y arms are locked
|