Message ID: 11558     Entry time: Wed Sep 2 01:31:22 2015     In reply to: 11555
Author: ericq 
Type: Update 
Category: IOO 
Subject: IMC loop shapes 

The promised historical comparisons follow. The crossover looks mostly the same as before. There is a new feature in the OLG at 50-60kHz; what could've changed about the EOM path in that time?

 

Attachment 1: imc_olg_trend.pdf  43 kB  | Hide | Hide all
imc_olg_trend.pdf
Attachment 2: imc_xover_trend.pdf  58 kB  | Hide | Hide all
imc_xover_trend.pdf