Entry  Mon Aug 24 16:10:07 2015, ericq, Update, SUS, ETMY Oplev laser power is falling ETMYsum_trend.pdf
    Reply  Mon Aug 24 16:46:49 2015, ericq, Update, SUS, ETMY Oplev laser power is falling OLsum_trend.pdf
       Reply  Thu Sep 3 08:53:55 2015, Steve, Update, SUS, ETMY Oplev laser power is falling ETMYoplev2y.png
Message ID: 11527     Entry time: Mon Aug 24 16:46:49 2015     In reply to: 11526     Reply to this: 11566
Author: ericq 
Type: Update 
Category: SUS 
Subject: ETMY Oplev laser power is falling 

Repeated for all optics, ETMY seems like the only one sharply dropping for now (PRM is all over the place and hard to gauge, since we often leave it partially- or mis-aligned):

 


Hacky bits:

Bash:

find /opt/rtcds/caltech/c1/burt/autoburt/snapshots/2015 -wholename "*00:0*"
| xargs ack --nogroup "OL_SUM_OUT16 1"
| grep -v 'SUS-MC'
| sed -e 's/.*2015/2015/g' -e 's/\/c1.*C1:SUS-/, /g' -e 's/_OL.*\([0-9]\..*$\)/, \1/g' -e 's/\//-/g'
| sort | uniq > allOL.txt

qontrols@pianosa|~ > head allOL.txt 
2015-Apr-10-00:07, BS, 1.146766113281250e+03
2015-Apr-10-00:07, ETMX, 1.597261328125000e+04
2015-Apr-10-00:07, ETMY, 4.331762207031250e+03
2015-Apr-10-00:07, ITMX, 6.488521484375000e+03
2015-Apr-10-00:07, ITMY, 1.387590234375000e+04
2015-Apr-10-00:07, PRM, 8.352053833007812e+02
2015-Apr-10-00:07, SRM, 6.099560928344727e+01
2015-Apr-1-00:07, BS, 1.180478149414062e+03
2015-Apr-1-00:07, ETMX, 1.584842480468750e+04

Python:

 

olsum = pd.read_csv('allOL.txt',parse_dates=True, names=['Date','Optic','Sum'])
olsum['Date'] = pd.to_datetime(olsum['Date']) # Automatic parsing didn't work for some reason
olpivot = olsum.pivot(index='Date',columns='Optic',values='Sum')
olpivot.plot()
Attachment 1: OLsum_trend.pdf  27 kB  | Hide | Hide all
OLsum_trend.pdf
ELOG V3.1.3-