Entry  Wed Aug 12 16:39:46 2015, Ignacio, Update, IOO, MISO WIener (T240-X and T240-Y) FF of MCL 6x
    Reply  Wed Aug 12 16:48:26 2015, Ignacio, Update, IOO, Better? Nope. MISO WIener (T240-X and T240-Y) FF of MCL 6x
Message ID: 11500     Entry time: Wed Aug 12 16:48:26 2015     In reply to: 11499
Author: Ignacio 
Type: Update 
Category: IOO 
Subject: Better? Nope. MISO WIener (T240-X and T240-Y) FF of MCL 

Last night, I also worked on a "better" (an improvement, I thought) of the MISO Wiener filter (T240-X and T240-Y witnesses) IIR filter. The FF results are shown below:

Filter:

T240-X

T240-Y

 

Training data + Predicted FIR and IIR subtraction:

Online subtraction results:

MCL
YARM

Subtraction performace:

 Although the predicted FIR and IIR results are "better" than the previous MISO filter, the subtraction performance for this filter is marginally better if not worse (both peak at 15 dB, in slightly different regions). 