Entry  Tue Jun 30 11:33:00 2015, Jamie, Summary, CDS, prepping for CDS upgrade 
    Reply  Wed Jul 1 19:16:21 2015, Jamie, Summary, CDS, CDS upgrade in progress 
       Reply  Tue Jul 7 18:27:54 2015, Jamie, Summary, CDS, CDS upgrade: progress! 2.9-RTS-OK.pngC1X04_GDS_TP.png
          Reply  Wed Jul 8 20:37:02 2015, Jamie, Summary, CDS, CDS upgrade: one step forward, two steps back 
             Reply  Wed Jul 8 21:02:02 2015, Jamie, Summary, CDS, CDS upgrade: another step forward, so we're back to where we started (plus a bit?) 
                Reply  Thu Jul 9 13:26:47 2015, Jamie, Summary, CDS, CDS upgrade: new mx 1.2.16 installed 
                   Reply  Thu Jul 9 16:50:13 2015, Jamie, Summary, CDS, CDS upgrade: if all else fails try throwing metal at the problem 
                      Reply  Mon Jul 13 01:11:14 2015, Jamie, Summary, CDS, CDS upgrade: current assessment 
                         Reply  Mon Jul 13 18:12:50 2015, Jamie, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                            Reply  Tue Jul 14 09:08:37 2015, Jamie, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                               Reply  Tue Jul 14 10:28:02 2015, ericq, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                                  Reply  Tue Jul 14 11:57:27 2015, jamie, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                            Reply  Tue Jul 14 16:51:01 2015, Jamie, Summary, CDS, CDS upgrade: problem is not disk access 
                               Reply  Wed Jul 15 13:19:14 2015, Jamie, Summary, CDS, CDS upgrade: reducing mx end-points as last ditch effort 
                                  Reply  Wed Jul 15 18:19:12 2015, Jamie, Summary, CDS, CDS upgrade: tentative stabilty? 
                                     Reply  Sat Jul 18 15:37:19 2015, Jamie, Summary, CDS, CDS upgrade: current status cds-good.pngsus-damped.png
Message ID: 11408     Entry time: Tue Jul 14 10:28:02 2015     In reply to: 11406     Reply to this: 11409
Author: ericq 
Type: Summary 
Category: CDS 
Subject: CDS upgrade: left running in semi-stable configuration 

There remains a pattern to some of the restarts, the following times are all reported as restart times. (There are others in between, however.)

daqd: Tue Jul 14 00:02:48 PDT 2015
daqd: Tue Jul 14 01:02:32 PDT 2015
daqd: Tue Jul 14 03:02:33 PDT 2015
daqd: Tue Jul 14 05:02:46 PDT 2015
daqd: Tue Jul 14 06:01:57 PDT 2015
daqd: Tue Jul 14 07:02:19 PDT 2015
daqd: Tue Jul 14 08:02:44 PDT 2015
daqd: Tue Jul 14 09:02:24 PDT 2015
daqd: Tue Jul 14 10:02:03 PDT 2015

Before the upgrade, we suffered from hourly crashes too:

daqd_start Sun Jun 21 00:01:06 PDT 2015
daqd_start Sun Jun 21 01:03:47 PDT 2015
daqd_start Sun Jun 21 02:04:04 PDT 2015
daqd_start Sun Jun 21 03:04:35 PDT 2015
daqd_start Sun Jun 21 04:04:04 PDT 2015
daqd_start Sun Jun 21 05:03:45 PDT 2015
daqd_start Sun Jun 21 06:02:43 PDT 2015
daqd_start Sun Jun 21 07:04:42 PDT 2015
daqd_start Sun Jun 21 08:04:34 PDT 2015
daqd_start Sun Jun 21 09:03:30 PDT 2015
daqd_start Sun Jun 21 10:04:11 PDT 2015

So, this isn't neccesarily new behavior, just something that remains unfixed. 

ELOG V3.1.3-