Entry  Tue Jun 30 11:33:00 2015, Jamie, Summary, CDS, prepping for CDS upgrade 
    Reply  Wed Jul 1 19:16:21 2015, Jamie, Summary, CDS, CDS upgrade in progress 
       Reply  Tue Jul 7 18:27:54 2015, Jamie, Summary, CDS, CDS upgrade: progress! 2.9-RTS-OK.pngC1X04_GDS_TP.png
          Reply  Wed Jul 8 20:37:02 2015, Jamie, Summary, CDS, CDS upgrade: one step forward, two steps back 
             Reply  Wed Jul 8 21:02:02 2015, Jamie, Summary, CDS, CDS upgrade: another step forward, so we're back to where we started (plus a bit?) 
                Reply  Thu Jul 9 13:26:47 2015, Jamie, Summary, CDS, CDS upgrade: new mx 1.2.16 installed 
                   Reply  Thu Jul 9 16:50:13 2015, Jamie, Summary, CDS, CDS upgrade: if all else fails try throwing metal at the problem 
                      Reply  Mon Jul 13 01:11:14 2015, Jamie, Summary, CDS, CDS upgrade: current assessment 
                         Reply  Mon Jul 13 18:12:50 2015, Jamie, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                            Reply  Tue Jul 14 09:08:37 2015, Jamie, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                               Reply  Tue Jul 14 10:28:02 2015, ericq, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                                  Reply  Tue Jul 14 11:57:27 2015, jamie, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                            Reply  Tue Jul 14 16:51:01 2015, Jamie, Summary, CDS, CDS upgrade: problem is not disk access 
                               Reply  Wed Jul 15 13:19:14 2015, Jamie, Summary, CDS, CDS upgrade: reducing mx end-points as last ditch effort 
                                  Reply  Wed Jul 15 18:19:12 2015, Jamie, Summary, CDS, CDS upgrade: tentative stabilty? 
                                     Reply  Sat Jul 18 15:37:19 2015, Jamie, Summary, CDS, CDS upgrade: current status cds-good.pngsus-damped.png
Message ID: 11384     Entry time: Tue Jun 30 11:33:00 2015     Reply to this: 11390
Author: Jamie 
Type: Summary 
Category: CDS 
Subject: prepping for CDS upgrade 

This is going to be a big one.  We're at version 2.5 and we're going to go to 2.9.3.

RCG components that need to be updated:

  • mbuf kernel module
  • mx_stream driver
  • iniChk.pl script
  • daqd
  • nds

Supporting software:

  • EPICS 3.14.12.2_long
  • ldas-tools (framecpp) 1.19.32-p1
  • libframe 8.17.2
  • gds 2.16.3.2
  • fftw 3.3.2

Things to watch out for:

  • RTS 2.6:
    • raw minute trend frame location has changed (CRC-based subdirectory)
    • new kernel patch
  • RTS 2.7:
    • supports "commissioning frames", which we will probably not utilize.  need to make sure that we're not writing extra frames somewhere
  • RTS 2.8:
    • "slow" (EPICS) data from the front-end processes is acquired via DAQ network, and not through EPICS.  This will increase traffic on the DAQ lan.  Hopefully this will not be an issue, and the existing network infrastructure can handle it, but it should be monitored.