40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue May 19 14:51:44 2015, ericq, Update, Modern Control, Brushing up on Wiener Filtering mclData.pngmclWiener.zip
    Reply  Tue May 19 17:53:38 2015, rana, Update, Modern Control, Brushing up on Wiener Filtering 
Message ID: 11310     Entry time: Tue May 19 14:51:44 2015     Reply to this: 11313
Author: ericq 
Type: Update 
Category: Modern Control 
Subject: Brushing up on Wiener Filtering 

As part of preparing for the SURF projects this summer, I grabbed ~50 minutes of MCL and STS_1 data from early this morning to do a little MISO wiener filtering. It was pretty straightforward to use the misofw.m code to achieve an offline subtraction factor of ~10 from 1-3Hz. This isn't the best ever, but doesn't compare so unfavorably to older work, especially given that I did no prefiltering, and didn't use all that long of a data stretch.

Code and plot (but not data) is attached. 

Attachment 1: mclData.png  386 kB  | Hide | Hide all
mclData.png
Attachment 2: mclWiener.zip  2 kB
ELOG V3.1.3-