Thu Feb 26 13:17:31 2015, ericq, Update, Computer Scripts / Programs, FB IO load
|
Thu Feb 26 13:55:59 2015, jamie, Update, Computer Scripts / Programs, FB IO load
|
Mon Mar 23 19:30:36 2015, rana, Update, Computer Scripts / Programs, rsync frames to LDAS cluster
|
Wed May 13 09:17:28 2015, rana, Update, Computer Scripts / Programs, rsync frames to LDAS cluster
|
Mon May 18 14:22:05 2015, ericq, Update, Computer Scripts / Programs, rsync frames to LDAS cluster
|
|
Message ID: 11077
Entry time: Thu Feb 26 13:55:59 2015
In reply to: 11076
Reply to this: 11161
|
Author: |
jamie |
Type: |
Update |
Category: |
Computer Scripts / Programs |
Subject: |
FB IO load |
|
|
We should use "ionice" to throttle the rsync. Use something like "ionice -c 3 rsync ..." to set the priority such that the rsync process will only work when there is no other IO contention. See "man ionice" for other options. |