40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Feb 11 04:08:53 2015, Jenne, Update, LSC, New Locking Paradigm? 
    Reply  Wed Feb 11 22:13:44 2015, Jenne, Update, LSC, New Locking Paradigm - LSC model changes 
       Reply  Thu Feb 12 01:43:09 2015, rana, Update, LSC, New Locking Paradigm - LSC model changes TF.gif
       Reply  Thu Feb 12 11:14:29 2015, Jenne, Update, LSC, New Locking Paradigm - Loop-gebra ALS_REFL_comboLockingCartoon_11Feb2015.PDFALS_REFL_comboLocking_11Feb2015.zip
          Reply  Thu Feb 12 11:59:58 2015, Koji, Update, LSC, New Locking Paradigm - Loop-gebra 
             Reply  Thu Feb 12 19:18:49 2015, Jenne, Update, LSC, New Locking Paradigm - Loop-gebra 
                Reply  Fri Feb 13 03:28:34 2015, rana, Update, LSC, New Locking Paradigm - Loop-gebra 
                   Reply  Sat Feb 14 20:20:24 2015, Jenne, Update, LSC, ALS fool cartoon ALSfool_LoopDiagram.pngALSfool_LoopDiagram.graffle.zip
                      Reply  Tue Feb 17 04:04:32 2015, Jenne, Update, LSC, ALS fool math OpenLoopGainComparison_16Feb2015.pngCancellationTFs_DecouplingIsArefl.png
                         Reply  Tue Feb 17 16:36:08 2015, Jenne, Update, LSC, ALS fool math ALSfool_LoopDiagram_17Feb2015.pngALS_REFL_comboLocking_16Feb2015.nb.zip
       Reply  Thu Feb 12 22:28:16 2015, Jenne, Update, LSC, New Locking Paradigm - LSC model changes, screens modified 
          Reply  Sat Mar 7 19:15:17 2015, Jenne, Update, LSC, Modified zero crossing triggering LatchLogic_6March2015.png
    Reply  Thu Feb 12 03:43:54 2015, ericq, Update, LSC, 3F PRMI at zero ALS CARM Feb12_negativeTR.png
Message ID: 11011     Entry time: Thu Feb 12 11:14:29 2015     In reply to: 11007     Reply to this: 11012
Author: Jenne 
Type: Update 
Category: LSC 
Subject: New Locking Paradigm - Loop-gebra 

I have calculated the response of this new 2.5 loop system.

The first attachment is my block diagram of the system.  In the bottom left corner are the one-hop responses from each green-colored point to the next.  I use the same matrix formalism that we use for Optickle, which Rana described in the loop-ology context in http://nodus.ligo.caltech.edu:8080/40m/10899

In the bottom right corner is the closed loop response of the whole system.

 

Also attached is a zipped version of the mathematica notebook used to do the calculation.

EDIT, JCD, 17Feb2015:  Updated loop diagram and calculation:  http://131.215.115.52:8080/40m/11043

Attachment 1: ALS_REFL_comboLockingCartoon_11Feb2015.PDF  116 kB  Uploaded Wed Feb 11 22:21:09 2015  | Hide | Hide all
ALS_REFL_comboLockingCartoon_11Feb2015.PDF
Attachment 2: ALS_REFL_comboLocking_11Feb2015.zip  2 kB  Uploaded Wed Feb 11 22:21:36 2015