40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Wed Nov 5 01:58:54 2014, ericq, Update, LSC, 3F RFPD RF spectra  
|
Wed Nov 5 11:09:44 2014, Koji, Update, LSC, 3F RFPD RF spectra
|
Wed Nov 5 22:25:42 2014, ericq, Update, LSC, 3F RFPD RF spectra
|
Thu Nov 6 01:58:55 2014, Koji, Update, LSC, 3F RFPD RF spectra
|
Thu Nov 6 11:49:58 2014, ericq, Update, LSC, 3F RFPD RF spectra
|
Thu Nov 6 14:41:49 2014, Koij, Update, LSC, 3F RFPD RF spectra
|
Fri Nov 7 02:21:12 2014, ericq, Update, LSC, 3F RFPD RF spectra
|
Fri Nov 7 14:41:18 2014, ericq, Update, LSC, 3F RFPD RF spectra 
|
Fri Nov 7 16:15:53 2014, Jenne, Update, LSC, 3F RFPD RF spectra
|
Sat Nov 8 11:35:05 2014, rana, Update, LSC, 3F RFPD RF spectra
|
Mon Nov 10 18:11:57 2014, ericq, Update, LSC, 3F RFPD RF spectra
|
|
Message ID: 10689
Entry time: Sat Nov 8 11:35:05 2014
In reply to: 10686
|
Author: |
rana |
Type: |
Update |
Category: |
LSC |
Subject: |
3F RFPD RF spectra |
|
|
I think 'saturation' here is a misleading term to think about. In the RF amplifiers, there is always saturation. What we're trying to minimize is the amount of distorted waveforms appearing at 3f and 15f from the other large peaks. Usually for saturation we are worried about how much the big peak is getting distorted; not the case for us. |