40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Aug 11 21:03:48 2014, ericq, rana, Summary, IOO, MC demod measurement 
    Reply  Mon Aug 11 22:07:31 2014, Koji, Summary, IOO, MC demod measurement 
    Reply  Mon Aug 11 23:32:54 2014, ericq, Summary, IOO, MC demod measurement MCDemod.pdfdemodLP.txt
Message ID: 10365     Entry time: Mon Aug 11 23:32:54 2014     In reply to: 10363
Author: ericq 
Type: Summary 
Category: IOO 
Subject: MC demod measurement 

Here's the magnitude plot of the board TF. As mentioned above, this was done with Marconi+Scope, so we were not able to get the phase of this transfer function. 

MCDemod.pdf

Oddly enough, the bump that I saw is not included in Minicircuit's data on the SCLF-5.

Attachment 2: demodLP.txt  274 Bytes  Uploaded Sun Dec 21 17:17:20 2014  | Hide | Hide all
# F(Hz) RMS(mV)
1035 38.6
2031 38.47
4031 38.47
8032 38.38
16030 38.10
32030 38.10
64030 38.16
128000 38.10
256000 38.22
... 12 more lines ...