40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Aug 11 21:03:48 2014, ericq, rana, Summary, IOO, MC demod measurement 
    Reply  Mon Aug 11 22:07:31 2014, Koji, Summary, IOO, MC demod measurement 
    Reply  Mon Aug 11 23:32:54 2014, ericq, Summary, IOO, MC demod measurement MCDemod.pdfdemodLP.txt
Message ID: 10364     Entry time: Mon Aug 11 22:07:31 2014     In reply to: 10363
Author: Koji 
Type: Summary 
Category: IOO 
Subject: MC demod measurement 

SCLF-5!? It's surprising as the cut off of the OLTF is just above 1Hz. cf this entry

This means that not the demod board but MC or FSS boards seem to have large attenuation above 1MHz.

In this situation, does SCLF-10/10.7 really help us?