Message ID: 10356     Entry time: Fri Aug 8 18:08:12 2014     In reply to: 10354
Author: Koji 
Type: Summary 
Category: IOO 
Subject: MC servo analysis 

The closed gain I meant is the AO path: Use IN2 to excite the MC loop and measure IN1 using MON2(?).
In order to obtain the open loop gain from this meausrement, the gain mismatching needs to be compensated, though.

This measurement is to correctly predict the AO path response from the open loop transfer function.

Anyway, the openloop gain seems nicely measured. I'll try to predict AO path response from this.