40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Jul 16 22:17:40 2014, Akhil, Summary, Electronics, Bode Plots and complete Characterization of Frequency Counter Phase_Data.zipBode100MHz.png
    Reply  Wed Jul 16 23:02:16 2014, Koji, Summary, Electronics, Bode Plots and complete Characterization of Frequency Counter 
       Reply  Fri Jul 18 19:32:50 2014, Akhil, Summary, Electronics, Filters used inside the Frequency Counter TheoreticalGainPlot.pngTFexpected.png
          Reply  Mon Jul 21 12:16:27 2014, Akhil, Summary, Electronics, Filters used inside the Frequency Counter FC_TF_Characterization.png
Message ID: 10246     Entry time: Mon Jul 21 12:16:27 2014     In reply to: 10239
Author: Akhil 
Type: Summary 
Category: Electronics 
Subject: Filters used inside the Frequency Counter 

The expected bode plots for such a filter with L= 4 is attached and compared with the measured.

RXA: When comparing two things, please put them onto the same plot so that they can be compared.

Attachment 1: FC_TF_Characterization.png  20 kB  Uploaded Mon Jul 21 15:25:30 2014  | Hide | Hide all
FC_TF_Characterization.png
ELOG V3.1.3-