40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Jun 16 23:15:44 2014, Jenne, Update, LSC, IFO alignment recovery Note_061614_230723_0.jpg
    Reply  Tue Jun 17 17:14:14 2014, Manasa, Update, LSC, IFO alignment recovery 
       Reply  Tue Jun 17 21:49:13 2014, Jenne, Update, LSC, IFO alignment recovery 
    Reply  Wed Jun 18 11:57:44 2014, not Jenne, Update, LSC, IFO alignment recovery 
Message ID: 10051     Entry time: Tue Jun 17 17:14:14 2014     In reply to: 10047     Reply to this: 10053
Author: Manasa 
Type: Update 
Category: LSC 
Subject: IFO alignment recovery 

 1. Recovered MC alignment and locked it manually after the ottavia cron failed to help.

2. Measured the MC spots and could not get the MC spots better looking than this.

spot positions in mm (MC1,2,3 pit MC1,2,3 yaw):
[1.6609930611758554, -1.4655939584833202, 1.3133188677545831, -1.9483764375494121, -1.6539541350121174, -0.8862744551298497]

3. Realigned the beams to the MC WFS and enabled WFS servo.

MC Trans SUM is ~17000 counts and MC REFL is ~0.5 counts.

To-do list

MC spots

MC WFS

IOO QPDS center

BBPD char

Recover REFL 33

MC REFL

MC autolocker cron

ELOG V3.1.3-