40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Jun 16 21:56:53 2014, Jenne, Update, Computer Scripts / Programs, fstab updates, MC autolocker running, FSS slow loop alive 
    Reply  Tue Jun 17 12:04:40 2014, manasa, Update, Computer Scripts / Programs, MC autolocker NOT running, FB needs some attention FE_red.png
       Reply  Tue Jun 17 16:52:40 2014, ericq, Update, Computer Scripts / Programs, autolocker confusion 
          Reply  Tue Jun 17 19:39:29 2014, rana, Update, Computer Scripts / Programs, autolocker confusion 
             Reply  Wed Jun 18 11:28:19 2014, Manasa, Update, Computer Scripts / Programs, autolocker confusion 
                Reply  Wed Jun 18 13:29:48 2014, rana, Update, Computer Scripts / Programs, autolocker confusion 
                   Reply  Wed Jun 18 17:38:14 2014, Jenne, Update, Computer Scripts / Programs, autolocker running again 
                      Reply  Thu Jun 19 16:49:15 2014, rana, Update, Computer Scripts / Programs, autolocker running again 
                         Reply  Thu Jun 19 22:04:23 2014, ericq, Update, Computer Scripts / Programs, caget/caput now return in reasonable time 
                            Reply  Fri Jun 20 09:46:49 2014, manasa, Update, IOO, MC WFS servo turned ON 
                            Reply  Fri Jun 20 19:07:44 2014, rana, Update, Computer Scripts / Programs, op340m DNS 
                               Reply  Tue Jun 24 22:46:15 2014, ericq, Update, Computer Scripts / Programs, op340m crons 
       Reply  Tue Jun 17 17:04:26 2014, ericq, Update, Computer Scripts / Programs, FB troubles 
Message ID: 10048     Entry time: Tue Jun 17 12:04:40 2014     In reply to: 10046     Reply to this: 10049   10050
Author: manasa 
Type: Update 
Category: Computer Scripts / Programs 
Subject: MC autolocker NOT running, FB needs some attention 

MC autolocker and Ottavia

I assume that the MC was left with a fully functioning autolocker enabled and running on ottavia last night.

But as of this morning, the MC autolocker is NOT running alright. The MC was in an unlocked state and the autolocker has been doing nothing to the servo sliders.  I think this was the state of MC since last night as seen on the stripchart.

Since the autolocker has been left to run on ottavia, I tried to look at the cronlogs to see if it running the autolocker script at all. I looked at the list on ottavia and it has the MCautlocker on it cronjobs list and yet doing nothing.

Later, I did a softreboot on ottavia when I could not ssh into it from rossa or pianosa. ssh to ottavia now works just fine.

I am leaving Ottavia at this and returning to the more important job of fixing the MC. I locked the MC manually and am now working on the alignment.

 

Framebuilder

Also, the CDS FE status screen had red lights blinking as if it required an 'mxstream restart'. I did the same and it did not fix the problem. So I tried to restart fb using the usual 'telnet fb 8087'; but could not restart fb that way.

Attached: FE status screen