[Rana, Jenne]
Mc autolocker:
MC autolocker is running. The trouble was with caput and caget and cavput on Pianosa. Rana has switched those lines in mcup and mcdown over to ezcaread and ezcawrites, and that seems to have fixed things. For the MC2tickleON and -OFF scripts, we left the caput and caget and cavput, and saw that they do run successfully on Ottavia. (We tried testing again on Pianosa, and now it seems to be okay with cavput, but we promise it was hanging up on this earlier this evening.) Anyhow, it's all a bit confusing, but it seems to be running fine now.
The autolocker is now running on Ottavia, and Rana is putting it into Ottavia's cronjob list, and commented it out on op340m.
fstab changes:
We have removed the option "all_squash" from /etc/exports on Chiara (both lines). We then checked that the files have ownership "controls controls" on Chiara, Pianosa and Rossa. Ottavia still has ownership of "nobody nogroup", so we still need to figure that out.
FSS slow loop:
We confirmed that the slow loop is running. Also, since caput and caget seem to take a while, and the real PID integral gain is the value that we set times a sampling rate, the effective gain had changed. So, Rana compensated by changing C1:PSL-FSS_SLOWKI from 0.03 to 0.1.
Other thoughts:
Do we have an autoburt saver on another computer, in addition to op340m? (It's in the op340m crontab list) We really only want one of these at a time.
|