Entry  Sat Jul 31 11:54:20 2010, Aidan, Computing, SLED, SLED Test Day 5 - Re-tuned current set-point control voltage 
Entry  Wed Aug 4 09:57:38 2010, Aidan, James, Computing, Hartmann sensor, RMS measurements with Hartmann sensor rms_analyze_centroids_aidan.pdfRMS_WonCode.pngRMS_WonCodeLessPrism.png
Entry  Wed Aug 18 18:38:11 2010, Aidan, Computing, Hartmann sensor, Hartmann sensor code test_HS_Classes.mHS_Image.mHS_Centroids.mHWS_code_output.pngHWS_input_image.png
Entry  Thu Nov 4 13:31:19 2010, Won Kim, Computing, Hartmann sensor, Frame Grabber SDK installation 
Entry  Tue Nov 23 06:15:08 2010, Won, Computing, Hartmann sensor, Image folder structure image_folders.png
Entry  Tue Nov 30 11:01:19 2010, Aidan, Computing, General, New workstation added in TCS Lab. New Static IP 
Entry  Tue Nov 30 11:03:19 2010, Aidan, Computing, Frame Grabber, EDT frame grabber works under Ubuntu 
    Reply  Mon Feb 28 17:33:07 2011, Aidan, Computing, Hartmann sensor, Hartmann Seidel abberation channels in frame builder 
Entry  Mon Feb 28 17:56:32 2011, Aidan, Computing, Hartmann sensor, Got HWS code running and interface to EPICS 
Entry  Thu Mar 3 07:30:18 2011, Won, Computing, Hartmann sensor, Effect of high pixel count on rms 11x
Entry  Tue Mar 8 11:30:26 2011, Aidan, Computing, Hartmann sensor, Hartmann sensor code changes and NTP server 
Entry  Tue Mar 8 18:28:14 2011, Aidan, Computing, General, TO DO notes 
Entry  Tue Mar 8 18:48:00 2011, Aidan, Computing, Hartmann sensor, HWS code is running and recording centroids 
Entry  Wed Mar 9 01:00:12 2011, Peter Veitch, Won Kim, Computing, Hartmann sensor, Control of frame rate usign external trigger 
Entry  Fri Apr 1 02:41:55 2011, Won, Computing, Hartmann sensor, exposure time and reproducibility of centroids 9x
Entry  Fri Apr 1 09:51:45 2011, Aidan, Computing, Hartmann sensor, Prism measurement Hartmann_Sensor_prism_measurement_2011-03-31.pdfHartmann_Sensor_Prism_measurement_times_series_2011-03-31.pdf
Entry  Tue Apr 12 22:30:59 2011, Aidan, Computing, EPICS, Installed the thermistor on the Hartmann plate/created MEDM ADC Input screen Screenshot-TCS_athena01_input_screen.adl.png
Entry  Tue Apr 12 22:46:27 2011, Aidan, Computing, EPICS, Added temperature sensor channels to the frame builder and restarted fb1 
Entry  Mon Apr 18 15:03:49 2011, Aidan, Computing, DAQ, Athena DAC channels hooked up to BNC patch panel 
Entry  Fri Apr 22 19:51:37 2011, Aidan, Computing, EPICS, pyepics installed on princess_sparkle start_test_channels.py
Entry  Sun Apr 24 18:31:18 2011, Aidan, Computing, Network architecture, Added hosts and network drives on TCS machines 
Entry  Mon Apr 25 16:28:27 2011, Aidan, Joe, Computing, Network architecture, Fixed problem network drive fb1:/cvs on Ubuntu & CentOS machines 
Entry  Tue May 10 00:55:08 2011, Won, Computing, Hartmann sensor, Matlab Compiler and Matlab Compiler Runtime 
Entry  Wed May 11 09:07:03 2011, Aidan, Computing, Hartmann sensor, Changed ownership of /opt/EDTpdv 
Entry  Wed May 11 18:38:47 2011, Aidan, Computing, Hartmann sensor, test_HS binary test_HS.zip
    Reply  Wed May 11 18:44:54 2011, Aidan, Computing, Hartmann sensor, Matlab Compiler and Matlab Compiler Runtime 
Entry  Tue May 17 16:08:02 2011, Aidan, Computing, Hartmann sensor, Write speed of the frame grabber to file max_frame_rate_data.txt
Entry  Wed May 18 18:52:12 2011, Aidan, Computing, Hartmann sensor, Test of position modulation algorithm galvo_mirror_experiment.jpg2011-05-18_gaussian_beam_with_galvo_constant.pdf2011-05-18_gaussian_beam_with_galvo.pdf
Entry  Fri Sep 2 14:41:48 2011, Aidan, Computing, Hartmann sensor, QFLD-950-3S long term test finished 
Entry  Mon May 13 14:09:02 2013, Zach, Computing, DAQ, C2ATF model rebuilt 
Entry  Thu Dec 15 14:02:01 2016, Aidan, Computing, Network architecture, Correct network settings for Ubuntu 14 in /etc/network/interfaces IMG_8148.JPG
    Reply  Fri Dec 16 10:41:33 2016, Aidan, Computing, Network architecture, Correct network settings for Ubuntu 14 in /etc/network/interfaces 
Entry  Wed Oct 11 19:14:16 2017, Jon Richardson, Computing, Electronics, Replaced TCS Monitor 
Entry  Fri Oct 13 18:35:29 2017, Jon Richardson, Computing, Electronics, Installed Maku Ethernet CCD Camera IMG_2287.JPG
    Reply  Tue Oct 24 10:19:53 2017, Jon Richardson, Computing, Electronics, Installed Maku Ethernet CCD Camera 
Entry  Tue Oct 24 15:05:57 2017, Jon Richardson, Computing, Electronics, Installed a Realtime Beam Profiler for the Mako CCD Camera 
Entry  Wed Oct 25 15:34:14 2017, Jon Richardson, Computing, Frame Grabber, Mako CCD Camera Code is Fixed 
Entry  Thu Oct 26 10:21:28 2017, Aidan, Computing, , Beam size EPICS channels added to TCS-WS softIoc 
    Reply  Thu Oct 26 10:31:31 2017, Aidan, Computing, DAQ, Beam size EPICS channels added to TCS-WS softIoc 
    Reply  Thu Oct 26 10:45:44 2017, Aidan, Computing, DAQ, Beam size EPICS channels added to TCS-WS softIoc FullSizeRender_10.jpg
Entry  Tue Oct 31 14:37:49 2017, Aidan, Computing, DAQ, New Acromag units for AWC experiments - XT1221 ans XT1541 
Entry  Thu Nov 9 14:18:56 2017, Aidan, Computing, DAQ, FB4 ip address has changed 
Entry  Tue Nov 14 19:08:00 2017, Jon Richardson, Computing, Network architecture, Rsync Server for Automatic LDAS Backups 
Entry  Mon Feb 5 15:08:06 2018, Aidan, Computing, DAQ, Frame builder clock is totally wrong 
    Reply  Wed May 30 18:50:05 2018, awade, Computing, DAQ, Rebooted fb4 
    Reply  Wed May 30 18:59:49 2018, awade, Computing, DAQ, FB4 ip address has changed 
Entry  Thu Aug 16 11:52:27 2018, Aidan, Computing, DAQ, Added AWC thermocouple reader back to acromag1 
    Reply  Wed Oct 17 16:17:45 2018, awade, Aidan, Computing, DAQ, Added AWC thermocouple reader back to acromag1 TCSIOCFILS.tar.gz
Entry  Tue Dec 4 16:57:08 2018, Aidan, Computing, Hartmann sensor, Updated GIT version of HWS code 