  196   Wed Oct 25 15:34:14 2017 Jon RichardsonComputingFrame GrabberMako CCD Camera Code is Fixed

I fixed a bug in how the raw Mako CCD camera images are being read into memory. The bmp files turn out to have a block memory layout that broke my in-place reader.

  245   Mon Jul 26 16:23:03 2021 AidanMiscFloodLab flooded from broken pipe leading to sump room

 

Koji: QIL/TCS entrance flooding. Check your lab

Anchal: Can someone take a look at CTN too?

Koij: TCS needs more people @aidan

Koji: CTN ok

Aidan: On my way

Shruti: Cryo seems fine

Aidan: There was a leak in a pipe in the wall of B265A. It was coming from the building air conditioner condensation overflow. Facilities has fixed the pipe and is working on clean-up

Attachment 1: IMG_3881.MOV
  246   Tue Jul 27 08:39:33 2021 AidanMiscFloodTuesday (27-Jul) morning check - lab looks okay

I checked the lab this morning. It was dry and there wall was in the same state as yesterday.

Attachment 1: Image_Pasted_at_2021-7-27_08-38-2.jpeg
Image_Pasted_at_2021-7-27_08-38-2.jpeg
Attachment 2: Image_Pasted_at_2021-7-27_08-38.jpeg
Image_Pasted_at_2021-7-27_08-38.jpeg
  247   Thu Aug 12 16:13:44 2021 AidanLab InfrastructureFloodCarpentry shop removed wet plaster sections from the wall - it's drying for a few days

The carpentry shop removed wet plaster sections from the wall following the flood (process was gentle scraping of wet plaster flakes, supervised by me). The wet section of wall needs a few days to dry and then they will plaster and paint it.

 

Attachment 1: IMG_4139.jpg
IMG_4139.jpg
  248   Wed Aug 25 11:28:56 2021 AidanMiscFloodLab flooded from broken pipe leading to sump room

11:29AM - Lab has flooded again this morning. I'm calling PMA. Looks to be the same issue as before.

Quote:

 

Koji: QIL/TCS entrance flooding. Check your lab

Anchal: Can someone take a look at CTN too?

Koij: TCS needs more people @aidan

Koji: CTN ok

Aidan: On my way

Shruti: Cryo seems fine

Aidan: There was a leak in a pipe in the wall of B265A. It was coming from the building air conditioner condensation overflow. Facilities has fixed the pipe and is working on clean-up

 

  249   Thu Aug 26 09:00:39 2021 AidanMiscFloodLab flooded from broken pipe leading to sump room

Some photos of water and clean-up.

Summary: I came into the lab around 11:30AM and found water on the floor in the changing room outside QIL/TCS. Turns out the condesation overflow pipe from the AC blew out again. This time near the ceiling. Water was on the floor but also had sprayed a little onto the tool chest and East optical table. A few optics got wet on the table. Initial inspection looks like electronics were spared with the exception of the "broken" spectrum analyzer that was on the floor. 

Facilities came in and cleaned up the water. A small amount got into QIL but stayed near the door as the lab floor slopes up from the door area. They fixed the pipe and were looking into whether there was a blockage cuasing this problem. PMA was notified and John Denhart is coordinating follow-up.

Triage effort: given the AC was still active, John and I strung a temporary tarp across the two tables to block any spray.

Quote:

11:29AM - Lab has flooded again this morning. I'm calling PMA. Looks to be the same issue as before.

Quote:

 

Koji: QIL/TCS entrance flooding. Check your lab

Anchal: Can someone take a look at CTN too?

Koij: TCS needs more people @aidan

Koji: CTN ok

Aidan: On my way

Shruti: Cryo seems fine

Aidan: There was a leak in a pipe in the wall of B265A. It was coming from the building air conditioner condensation overflow. Facilities has fixed the pipe and is working on clean-up

 

 

Attachment 1: 20210825_-_TCS_Lab_Flood_-_compressed.pdf
20210825_-_TCS_Lab_Flood_-_compressed.pdf 20210825_-_TCS_Lab_Flood_-_compressed.pdf 20210825_-_TCS_Lab_Flood_-_compressed.pdf 20210825_-_TCS_Lab_Flood_-_compressed.pdf 20210825_-_TCS_Lab_Flood_-_compressed.pdf 20210825_-_TCS_Lab_Flood_-_compressed.pdf 20210825_-_TCS_Lab_Flood_-_compressed.pdf 20210825_-_TCS_Lab_Flood_-_compressed.pdf
  143   Thu Apr 28 22:48:47 2011 AidanLab InfrastructureElectronicsBNC Cables from HWS table to rack

 I labelled and strung 8 of the 16 custom 40' BNC cables from L-Com between the HWS table and the BNC feed-through on the rack. Each cable is labelled HWS TABLE CHxx where 01<= xx <= 08. I'm going to leave the other 8 until we have room in the BNC feedthrough on the rack.

  185   Wed May 24 09:58:17 2017 AidanElectronicsElectronicsTemperature sensor batteries swapped in TCS Lab

I noticed that the TCS lab temperature sensor batteries died. Apparently they died two days ago. I swapped in some new batteries this morning.
 

  189   Wed Oct 11 19:14:16 2017 Jon RichardsonComputingElectronicsReplaced TCS Monitor

I replaced the dead 24" monitor on the work bench, which is connected to the video multiplexer. Mike Pedraza was kind enough to bring us us a new one and take away the old one.

  192   Fri Oct 13 18:35:29 2017 Jon RichardsonComputingElectronicsInstalled Maku Ethernet CCD Camera

I installed the Maku Gigabit CCD camera driver software on the hws-ws machine. The camera viewer can be opened from the terminal (from any directory) with the command

$ZimbaViewer

and there is also a shortcut icon on the desktop. The camera is ocurrently on the subnet at 10.0.1.157 and is configured to get its IP via DHCP. We can assign it a static IP if we'd like to keep it on the network permanently.

I left the camera mounted on the CO2 laser table. It's connected and ready to use.

Attachment 1: IMG_2287.JPG
IMG_2287.JPG
  194   Tue Oct 24 10:19:53 2017 Jon RichardsonComputingElectronicsInstalled Maku Ethernet CCD Camera

There is an SDK for the camera with compiled examples. For a really quick image grab from the command line, use the following:

/opt/Vimba_2_1/VimbaC/Examples/Bin/x86_64bit/SynchronousGrab

This will produce a BMP image. We should probably recompile the C code to produce a 16-bit TIFF image.

Quote:

I installed the Maku Gigabit CCD camera driver software on the hws-ws machine. The camera viewer can be opened from the terminal (from any directory) with the command

$ZimbaViewer

and there is also a shortcut icon on the desktop. The camera is ocurrently on the subnet at 10.0.1.157 and is configured to get its IP via DHCP. We can assign it a static IP if we'd like to keep it on the network permanently.

I left the camera mounted on the CO2 laser table. It's connected and ready to use.

 

  195   Tue Oct 24 15:05:57 2017 Jon RichardsonComputingElectronicsInstalled a Realtime Beam Profiler for the Mako CCD Camera

Aidan found a C demo code for acquiring a single image from the Mako CCD camera and saving it to disk (SynchronousGrab -- aliased on tcs-ws as makoGrab). I wrapped that inside my realtime HWS beam profiler code to create a realtime beam profiler for the Mako camera. The interface is identical to that for the HWS.

The Mako camera is running on the tcs-ws machine (10.0.1.168) and is launched from the console via the command

$stream_intensity_CIT

It is currently configured to write a raw image to the local frame archive every 5 seconds (it prints the write location in the console), which can be disabled by setting the "-d" flag.

  25   Mon May 3 17:42:20 2010 AidanComputingEPICSEPICS install by Alex

Alex Ivanov came in on Friday and demonstrated his EPICS kung-fu. His EPICS knig-fu is strong.

We fixed the IP address of the Hartmann machine, renamed it hartmann, and mounted the cvs drives from the frame builder. - including the EPICS base from that machine. In principle, with a new softIoc, this should have been enough to run EPICS on the hartmann machine. However, whilst the softIoc would start, it wouldn't broadcast any channels. Eventually we figured out that this was because of the Windows Virtualization adding another IP address to the hartmann machine (revealed with /sbin/ifconfig). So we removed the virtualization system and then EPICS seemed to broadcast much better.

The minutia of install isshown in the history files for the controls and root users - attached.

 

Attachment 1: history.txt
    1  cd
    2  mkdir -p rpmbuild/{BUILD,RPMS,SOURCES,SPECS,SRPMS}
    3  echo '%_topdir %(echo $HOME)/rpmbuild' > .rpmacros
    4  ls
    5  cd rpmbuild/
    6  rpm -i http://mirror.centos.org/centos/5/updates/SRPMS/kernel-2.6.18.15.1.el5.src.rpm 2
    7  cd ..
    8  rpm -i http://mirror.centos.org/centos/5/updates/SRPMS/kernel-2.6.18.15.1.el5.src.rpm 2>&1 | grep -v mockb
    9  rpm -i http://mirror.centos.org/centos/5/updates/SRPMS/kernel-2.6.18-164.15.1.e15.src.rpm 2>&1 | grep -v mockb
   10  rpm -i http://mirror.centos.org/centos/5/updates/SRPMS/kernel-2.6.18-164.15.1.e15.src.rpm 2>&1 | grep -v mockb
... 183 more lines ...
Attachment 2: history_root.txt
    1  yum
    2  yum install gcc
    3  yum install make
    4  yum install tk
    5  yum install tcl
    6  yum install mm
    7  yum install kernel
    8  yum install source
    9  yum install include
   10  yum install kernel-source
... 797 more lines ...
  38   Tue May 18 09:33:44 2010 AidanComputingEPICSAdded defocus and other Hartmann sensor channels to EPICS and DAQ

 I've added the following channels to the HWS softIoc in /cvs/cds/caltech/target/softIoc/HWS.db

 

 

EPICS and DAQ restart procedure

  1. Kill the existing softIoc. Use a "ps -e | grep softIoc" command to determine the process id.
  2. After editing the HWS.db file restart the softIoc with the following command:
[controls@hartmann softIoc]$  /cvs/opt/epics-3.14.10-RC2-i386/base/bin/linux-x86/softIoc -S  HWS.cmd &
[3] 11280
[controls@hartmann softIoc]$ dbLoadRecords "HWS.db"
iocInit
Starting iocInit
############################################################################
## EPICS R3.14.10- $R3-14-10-RC2$ $2008/10/10 15:01:51$
## EPICS Base built Oct 28 2009
############################################################################
iocRun: All initialization complete

        3. Edit the /cvs/cds/caltech/chans/daq/C4TCS.ini file and kill the daqd process on fb1. It should restart automatically.

Done!

 

  85   Fri Jul 30 19:22:24 2010 AidanComputingEPICSWaveform Channel Access for storing centroids

 A waveform channel was added to the HWS softIoc on hartmann. This allows arrays of data to be stored in a single channel. It's not clear whether it is storing this data as a set of number or strings. However, the values can be changed by the following command:

caput -a -n C4:TCS-HWS_CENTROIDSX 5 1,2,3,4,5

Although the <no of values> entry doesn't seem to actual enforce anything - you can have more or less values than this in the array and they are still added to the channel. What does seem to be necessary is no spaces between the commas and the values of the array.

This also works:

[controls@fb1 cds]$ caput -a -n C4:TCS-HWS_CENTROIDSX 2 1,2,3n
Old : C4:TCS-HWS_CENTROIDSX          1,2,35.4342 
New : C4:TCS-HWS_CENTROIDSX          1,2,3n 
which suggests that this is really a string variable - even with the -n enforce. The cainfo command suggests this as well. 

[controls@fb1 cds]$ cainfo C4:TCS-HWS_CENTROIDSX
C4:TCS-HWS_CENTROIDSX
    State:         connected
    Host:          
    Access:        read, write
    Data type:     DBR_STRING (native: DBF_STRING)
    Element count: 1
 
 

Usage: caput [options] <PV name> <PV value>

       caput -a [options] <PV name> <no of values> <PV value> ...

  -h: Help: Print this message

Channel Access options:

  -w <sec>:  Wait time, specifies longer CA timeout, default is 1.000000 second

Format options:

  -t: Terse mode - print only sucessfully written value, without name

Enum format:

  Default: Auto - try value as ENUM string, then as index number

  -n: Force interpretation of values as numbers

  -s: Force interpretation of values as strings

Arrays:

  -a: Put array

      Value format: number of requested values, then list of values


 

  86   Fri Jul 30 21:19:05 2010 AidanComputingEPICSWaveform Channel Access for storing centroids

After some discussion with Frank we figured out how to edit the record type in HWS.db so that the waveform/array channel actually behaved like a numerical array and not like a single string. This just involved defining the data type and the element count in the record definition, like so:

record(waveform, "C4:TCS-HWS_CENTROIDSX")
{
field(EGU,"PIXELS")
field(HOPR,"1024")
field(LOPR,"0")
field(FTVL,"DOUBLE")
field(NELM,"1000")
}
 

and then when the ioc was rebooted, examination of the channel showed the following:

 

[controls@hartmann softIoc]$ cainfo C4:TCS-HWS_CENTROIDSX
C4:TCS-HWS_CENTROIDSX
    State:         connected
    Host:          hartmann:5064
    Access:        read, write
    Data type:     DBR_DOUBLE (native: DBF_DOUBLE)
    Element count: 1000
 
 
[controls@hartmann softIoc]$ caput -a -n C4:TCS-HWS_CENTROIDSX 10 1 2 3 4 5 6 7 8 9 10 11 12 13.1
Old : C4:TCS-HWS_CENTROIDSX 13 1 2 3 4 5 6 7 8 9 10 11 12 13.1 
New : C4:TCS-HWS_CENTROIDSX 13 1 2 3 4 5 6 7 8 9 10 11 12 13.1 
 
 
[controls@hartmann softIoc]$ caget C4:TCS-HWS_CENTROIDSX
C4:TCS-HWS_CENTROIDSX 1000 1 2 3 4 5 6 7 8 9 10 11 12 13.1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
 

 

Quote:

 A waveform channel was added to the HWS softIoc on hartmann. This allows arrays of data to be stored in a single channel. It's not clear whether it is storing this data as a set of number or strings. However, the values can be changed by the following command:

caput -a -n C4:TCS-HWS_CENTROIDSX 5 1,2,3,4,5

Although the <no of values> entry doesn't seem to actual enforce anything - you can have more or less values than this in the array and they are still added to the channel. What does seem to be necessary is no spaces between the commas and the values of the array.

This also works:

 

[controls@fb1 cds]$ caput -a -n C4:TCS-HWS_CENTROIDSX 2 1,2,3n
Old : C4:TCS-HWS_CENTROIDSX          1,2,35.4342 
New : C4:TCS-HWS_CENTROIDSX          1,2,3n 
which suggests that this is really a string variable - even with the -n enforce. The cainfo command suggests this as well. 

 

 

[controls@fb1 cds]$ cainfo C4:TCS-HWS_CENTROIDSX
C4:TCS-HWS_CENTROIDSX
    State:         connected
    Host:          
    Access:        read, write
    Data type:     DBR_STRING (native: DBF_STRING)
    Element count: 1
 
 

 

 

Usage: caput [options] <PV name> <PV value>

       caput -a [options] <PV name> <no of values> <PV value> ...

  -h: Help: Print this message

Channel Access options:

  -w <sec>:  Wait time, specifies longer CA timeout, default is 1.000000 second

Format options:

  -t: Terse mode - print only sucessfully written value, without name

Enum format:

  Default: Auto - try value as ENUM string, then as index number

  -n: Force interpretation of values as numbers

  -s: Force interpretation of values as strings

Arrays:

  -a: Put array

      Value format: number of requested values, then list of values


 

 

 

  134   Tue Apr 12 22:30:59 2011 AidanComputingEPICSInstalled the thermistor on the Hartmann plate/created MEDM ADC Input screen

I restarted the Athena box and created an MEDM screen that shows the 8 differential input voltages next to their corresponding inputs on the breakout terminal strip. See the attached image. The MEDM screen is located at /home/controls/TCS_athena01_input_screen.adl on tcs_daq.

Channel 1 in the Athena is taking the output from the first channel in the temperature sensing box. That is connect to an RTD in the Hartmann sensor. The three other resistors in the Wheatstone bridge that the RTD is connected to have resistances of 1130 Ohms. There is 7V across the bridge and it has 100x gain afterwards (50x gain stage + 2x gain in single to differential output). The thermistor has temperature dependence K = 0.00385 Ohms/Ohm/degree K for 1000Ohms at 0 degrees.

R = 1000*EXP(K *delta T)

delta T = LOG(R/1000)/K

 I have configured some EPICS channels on the softIoc on the Athena box to display the voltage across the thermistor, calculate its resistance and then calculate the temperature in a linear and exponential fashion. These are stored in /target/TCS_westbridge.db on tcs_daq.

 The calibration of DEGREES_LOG is incorrect (or at least, the sign is). Fix this please.

grecord(calc,"C4:TCS-HWS_THERM_VOLTS")
{
        field(SCAN,".1 second")
        field(INPA,"C4:TCS-ATHENA_ADC0")
        field(INPB,"C4:TCS-ATHENA_ADC8")
        field(CALC,"(A-B)/3276.8")
}
grecord(calc,"C4:TCS-HWS_THERM_OHMS")
{
        field(SCAN,".1 second")
        field(INPA,"C4:TCS-HWS_THERM_VOLTS")
        field(CALC,"(-1130)*((A/700)-0.5)/((A/700)+0.5)")
}
grecord(calc,"C4:TCS-HWS_THERM_DEGREES_LIN")
{
        field(SCAN,".1 second")
        field(INPA,"C4:TCS-HWS_THERM_OHMS")
        field(CALC,"(A-1000)*3.85")
}
grecord(calc,"C4:TCS-HWS_THERM_DEGREES_LOG")
{
        field(SCAN,".1 second")
        field(INPA,"C4:TCS-HWS_THERM_OHMS")
        field(CALC,"(LOGE(A/1000))/0.00385")
}

Attachment 1: Screenshot-TCS_athena01_input_screen.adl.png
Screenshot-TCS_athena01_input_screen.adl.png
  135   Tue Apr 12 22:46:27 2011 AidanComputingEPICSAdded temperature sensor channels to the frame builder and restarted fb1

Added the following to the frame builder in /cvs/cds/caltech/chans/daq/C4HWS.ini and restarted daqd as per instructions in http://nodus.ligo.caltech.edu:8080/TCS_Lab/29

 

[C4:TCS-HWS_THERM_VOLTS]
[C4:TCS-HWS_THERM_OHMS]
[C4:TCS-HWS_THERM_DEGREES_LIN]
[C4:TCS-HWS_THERM_DEGREES_LOG]

  140   Fri Apr 22 19:51:37 2011 AidanComputingEPICSpyepics installed on princess_sparkle

 I installed the pyepics package on princess_sparkle since this is much easier under Ubuntu than under CentOS.

  1. sudo apt-get install python-dateutil python-setuptools
  2. make sure that LD_LIBRARY_PATH points to EPICS libraries by echo $LD_LIBRARY_PATH
  3. sudo ldconfig
  4. sudo easy_install -U pyepics

Then I started the following python script ~/start_test_channels.py in the background on princess_sparkle. The EPICS channels are actually in an IOC on tcs_daq. They are all acquired by the frame builder at 16Hz.

 

 

 

 

Attachment 1: start_test_channels.py
#!/usr/bin/python
# a short script to output low frequency sine wave to EPICS channels

import epics
import math
import time
import os
import random

a = 0
... 70 more lines ...
  105   Tue Feb 8 13:02:26 2011 AidanElectronicsDelivery NoteThorlabs S322C 200W power head arrived

 The 200W Thermopile power head from Thorlabs arrive today. The scanned delivery note and calibration info are attached.

Attachment 1: Co2_200W_power_meter_delviery_note.pdf
Co2_200W_power_meter_delviery_note.pdf
Attachment 2: Co2_200W_power_meter_calibration_info.pdf
Co2_200W_power_meter_calibration_info.pdf
  106   Fri Feb 18 13:26:23 2011 AidanThings to BuyDelivery NoteFirst parts of Bosch framing have arrived from Valin

The first pieces of the Bosch framing have arrived from Valin Corporation. These are just small pieces such as the fasteners and the gussets. There are no custom lengths of framing yet.

The details are in the attached Packing List. [1:25PM] I haven't verified that everything is there yet.

 

Attachment 1: Packing_List_01.pdf
Packing_List_01.pdf Packing_List_01.pdf
  108   Wed Feb 23 18:04:38 2011 AidanThings to BuyDelivery NoteFirst parts of Bosch framing have arrived from Valin

Quote:

The first pieces of the Bosch framing have arrived from Valin Corporation. These are just small pieces such as the fasteners and the gussets. There are no custom lengths of framing yet.

The details are in the attached Packing List. [1:25PM] I haven't verified that everything is there yet.

 

 Another box of Bosch stuff arrived in my office. The packing list is attached

Attachment 1: Packing_List_02.pdf
Packing_List_02.pdf Packing_List_02.pdf
  111   Thu Feb 24 13:35:41 2011 AidanThings to BuyDelivery NoteBosch framing has arrived

 The custom pieces of the Bosch framing have arrived. Transportation is currently moving them downstairs to the lab. The packing list is attached.

 

 

Attachment 1: Packing_List_03.pdf
Packing_List_03.pdf Packing_List_03.pdf
  117   Tue Mar 1 11:19:34 2011 AidanThings to BuyDelivery NoteMFF001 flipper mirror has arrived

 The Thorlabs MFF001 flipper mirror recommended by Bram has arrived. The delivery note is attached.

Attachment 1: Flipper_mirror_delivery_notice.pdf
Flipper_mirror_delivery_notice.pdf
  118   Tue Mar 1 11:21:37 2011 AidanThings to BuyDelivery NoteMore Bosch framing parts - angle connectors

 Another box of Bosch framing parts arrived today. The delivery note is attached.

Attachment 1: Packing_List_04.pdf
Packing_List_04.pdf
  124   Tue Mar 8 18:57:50 2011 AidanThings to BuyDelivery NoteFiber optics cable and Bosch Fastener
Attachment 1: deliveries_2011-03-08.pdf
deliveries_2011-03-08.pdf deliveries_2011-03-08.pdf
  126   Fri Mar 11 13:11:33 2011 AidanLab InfrastructureDelivery NoteMore Bosch connectors have arrived

 See attached delivery note ...

Attachment 1: Packing_List_05.pdf
Packing_List_05.pdf
  127   Wed Mar 16 15:05:47 2011 AidanLab InfrastructureDelivery NoteMore Bosch equipment has arrived

30mm T-junctions, grounding straps and T-slot covers have arrived

Quote:

 See attached delivery note ...

 

Attachment 1: Packing_List_06.pdf
Packing_List_06.pdf Packing_List_06.pdf Packing_List_06.pdf
  133   Mon Apr 4 13:13:23 2011 AidanThings to BuyDelivery NoteNewfocus 5102 mirrors and Firewire extension cable have arrived

 See attached delivery note ...

Attachment 1: receipt_mirrors.pdf
receipt_mirrors.pdf receipt_mirrors.pdf
  136   Sun Apr 17 14:59:36 2011 AidanThings to BuyDelivery NoteL-Com patch panel, Newport lenses, Thorlabs fibers delivery notes
Attachment 1: newport_lenses_2011-03.pdf
newport_lenses_2011-03.pdf
Attachment 2: L-Com_patch_panel_-_2011-03.pdf
L-Com_patch_panel_-_2011-03.pdf
Attachment 3: thorlabs_fiber_optic_cables_2011-03.pdf
thorlabs_fiber_optic_cables_2011-03.pdf thorlabs_fiber_optic_cables_2011-03.pdf
  243   Wed Oct 30 12:13:14 2019 JonMiscDelivery NoteNew lab hardware

Ian and I moved some new hardware into the lab, shown in the below photos. It is from the shipment of loaned equipment recently returned by Whitman College. 

Attachment 1:

  • ZnSe 1" dia. lenses (x2)
  • ZnSe 38.1 mm dia. windows (x2)

Attachment 2:

  • Synrad 20 W CO2 laser
  • Synrad laser controller

Attachment 3:

  • Intraaction Model GE modulator driver
  • Intraaction AOM

Attachment 4:

  • Second Intraaction Model GE modulator driver
  • Unknown optical cavity (was packaged together with the driver)

The ZnSe lenses and windows were put in the CO2 drawer of the optics cabinet. The CO2 laser, AOM, and modulator drivers were left packaged in boxes underneath the large laser table.

Attachment 1: IMG_3782.jpg
IMG_3782.jpg
Attachment 2: IMG_3783.jpg
IMG_3783.jpg
Attachment 3: IMG_3784.jpg
IMG_3784.jpg
Attachment 4: IMG_3785.jpg
IMG_3785.jpg
  3   Mon Dec 28 14:48:29 2009 AidanComputingDAQVME crate has a "new" CPU - needs to be configured

I installed a recycled VME crate in the electronics rack. It currently has a Baja 4700E CPU card in it - and this needs to be configured. We also have the following cards, which are not plugged in right now.

1. ICS-110A-32 Analogue-to-Digital Converter - the jumpers need to be set on this to give it a unique memory address in the VME bus.

2. D000186 LIGO-type Anti Image card.

The CPU card needs to be configured to search it's OS binaries on the network (in this case we're going to store them on the framebuilder in Rana's lab). These settings are accessed by plugging a serial cable into the front of the card and using a terminal window to access the menu system. There are some screen caps of this below. As the card is reset we get the Start-up screen and then we can either do nothing (and a full boot will take place) or we can press a key and access the menu. From there we can restart the boot process by entering "@" or we can change the boot settings by entering "c". These are shown below:

 

 

Attachment 1: VME_boot_02.jpg
VME_boot_02.jpg
Attachment 2: VME_boot_01.JPG
VME_boot_01.JPG
Attachment 3: VME_boot_03.jpg
VME_boot_03.jpg
  4   Tue Dec 29 16:05:09 2009 FrankComputingDAQbooting VME crates from fb1

 http://nodus.ligo.caltech.edu:8080/AdhikariLab/514

  5   Tue Dec 29 17:50:57 2009 AidanComputingDAQVME crate has proper boot settings

We fixed the start-up settings on the VME crate to look for a TCS startup file on fb0. The settings on the Baja 4700 are now:

Attachment 1: VME_tcs_boot_settings.jpg
VME_tcs_boot_settings.jpg
  6   Fri Jan 29 10:02:15 2010 AidanComputingDAQNew DAQ ordered

 On the advice of Ben Abbott, I've ordered the Diamond Systems Athena II computer w/DAQ, as well as an I/O board, solid state disk and housing for it. The delivery time is 4-6 weeks.

Diamond Systems Athena II

 

  138   Mon Apr 18 15:03:49 2011 AidanComputingDAQAthena DAC channels hooked up to BNC patch panel

 I added the four Athena DAC channels to the second BNC patch panel in the rack. At the moment there are only two EPICS channels in the database:

  • C4:TCS-ATHENA_DAC0
  • C4:TCS-ATHENA_DAC1

 

  181   Mon May 13 14:09:02 2013 ZachComputingDAQC2ATF model rebuilt

 ATF:1812

  198   Thu Oct 26 10:31:31 2017 AidanComputingDAQBeam size EPICS channels added to TCS-WS softIoc

These are also being written to frames on FB4.

Quote:

I've added a softIoc to TCS-WS to capture the beam size from the MAKO camera. The IOC is run using ...

controls@tcs-ws:~$ softIoc -S EPICS_IOC/iocBoot/iocfirst/st.cmd &

The st.cmd contains the following text:

controls@tcs-ws:~$ more EPICS_IOC/iocBoot/iocfirst/st.cmd

dbLoadDatabase "/home/controls/EPICS_IOC/db/beamSize.db"

iocInit

 

The db file is:

 

controls@tcs-ws:~$ more EPICS_IOC/db/beamSize.db

 

record(ai, "C4:AWC-MAKO_BEAMSIZE_WX")

{

    field(PREC,"3")

}

 

record(ai, "C4:AWC-MAKO_BEAMSIZE_WY")

{

    field(PREC,"3")

}

 

record(ai, "C4:AWC-MAKO_BEAM_POSN_X")

{

    field(PREC,"3")

}

 

 

record(ai, "C4:AWC-MAKO_BEAM_POSN_Y")

{

    field(PREC,"3")

}

 

 

  199   Thu Oct 26 10:45:44 2017 AidanComputingDAQBeam size EPICS channels added to TCS-WS softIoc

See attached photo for how data is written to frames ...

Quote:

These are also being written to frames on FB4.

Quote:

I've added a softIoc to TCS-WS to capture the beam size from the MAKO camera. The IOC is run using ...

controls@tcs-ws:~$ softIoc -S EPICS_IOC/iocBoot/iocfirst/st.cmd &

The st.cmd contains the following text:

controls@tcs-ws:~$ more EPICS_IOC/iocBoot/iocfirst/st.cmd

dbLoadDatabase "/home/controls/EPICS_IOC/db/beamSize.db"

iocInit

 

The db file is:

 

controls@tcs-ws:~$ more EPICS_IOC/db/beamSize.db

 

record(ai, "C4:AWC-MAKO_BEAMSIZE_WX")

{

    field(PREC,"3")

}

 

record(ai, "C4:AWC-MAKO_BEAMSIZE_WY")

{

    field(PREC,"3")

}

 

record(ai, "C4:AWC-MAKO_BEAM_POSN_X")

{

    field(PREC,"3")

}

 

 

record(ai, "C4:AWC-MAKO_BEAM_POSN_Y")

{

    field(PREC,"3")

}

 

 

 

Attachment 1: FullSizeRender_10.jpg
FullSizeRender_10.jpg
  201   Tue Oct 31 14:37:49 2017 AidanComputingDAQNew Acromag units for AWC experiments - XT1221 ans XT1541

I set up an Acromag DAC today with the fixed IP address 10.0.1.56. Last Friday Andrew and Antonio set up an ADC unit with fixed IP address 10.0.1.55. The former is for outputting a control voltager that goes to the driver for the heater on composite mirror we are testing. The latter is used to read the temperature of the thermocouple on the composite mirror. The thermocouple to voltage conversion is achieved with a Type K Thermocouple Amplifier unit from The Sensor Connection.

The temperature sensor channel is C4:AWC-TEMPMON_C. We took a couple of different measurements of temperature and calibrated the conversion from volts to Celsius as: C = 122.06*V -0.67

The new temperature sensor channel is now being recorded in the frames.

  202   Thu Nov 9 14:18:56 2017 AidanComputingDAQFB4 ip address has changed

We've had trouble logging into FB4. I access the computer directly in the AWC lab and found that the IP address had changed from 10.0.1.156 to 10.0.1.161.

I'm not sure how this happened. It's possible that the IP address is not set to a static value and FB4 was rebooted. I'm not familar with Debian so I don't know where to look to find whether the IP address is static or not.

The DAQD is still running.

  206   Mon Feb 5 15:08:06 2018 AidanComputingDAQFrame builder clock is totally wrong

The framebuilder on FB4 thinks the current time is 26-Jan-2018 6:18AM UTC. The date command on FB4 yields the correct date and time (5-Feb-2018 15:17 PST).

There is a major error with the framebuilder clock.

  212   Wed May 30 18:50:05 2018 awadeComputingDAQRebooted fb4

Time was still off by nine days as of yesterday.  I tried rebooting remotely to see if time would correct to system clock.  It didn't and fb4 hung.

Just manually restarted the box.  Now dataviewer is showing a 'Time Now'  of 5 Jan 1980.   

Not sure how to set the frame builder clock time. Ultimately the best solution is to have ADC cards but can we find a hack for now? Is it possible to run a cron script it to reset time to the computer time?

 

 

 

Quote:

The framebuilder on FB4 thinks the current time is 26-Jan-2018 6:18AM UTC. The date command on FB4 yields the correct date and time (5-Feb-2018 15:17 PST).

There is a major error with the framebuilder clock.

 

  213   Wed May 30 18:59:49 2018 awadeComputingDAQFB4 ip address has changed

Maybe you've resolved this now. I moved the DHCP allocation to 10.0.1.160 and above around that time because a bunch of misc devices were starting to populate the dynamically allocated IP space around there.  I'd say FB4 was not setup with a manual IP at the time.

 

Quote:

We've had trouble logging into FB4. I access the computer directly in the AWC lab and found that the IP address had changed from 10.0.1.156 to 10.0.1.161.

I'm not sure how this happened. It's possible that the IP address is not set to a static value and FB4 was rebooted. I'm not familar with Debian so I don't know where to look to find whether the IP address is static or not.

The DAQD is still running.

 

  221   Thu Aug 16 11:52:27 2018 AidanComputingDAQAdded AWC thermocouple reader back to acromag1
  • Thermcouple reader is plugged into an Acromag ADC (10.0.1.55)
  • acromag1 is now reading this in:
    • ~/modbus/iocBoot/iocTest/test_acromag.cmd (contains ip address of ADC)
    • ~/modbus/db/TEMPMONCHANS.db (contains the EPICS channel definitions and calibration of thermocouple reader)
  • C4:AWC-TEMPMON_C (output channel)

Restored work done in http://nodus.ligo.caltech.edu:8080/TCS_Lab/201

 

 

 

  222   Wed Oct 17 16:17:45 2018 awade, AidanComputingDAQAdded AWC thermocouple reader back to acromag1

Acromag IOC process was removed from PSL lab acromag1 computer a few months ago.  Aidan needs them again but it would be better if it were run from TCS lab computers.

An instance of the modbus IOC is now running on tcs-ws within a docker container.  Docker is named tcslabioc.  Configuration files are located in ~/modbus.  Instructions on how to use the docker are located in ATF:2249.  To install docker see google.

To set up the specific instance in the TCS lab run

>sudo docker run -dt --name tcslabioc -v /home/controls/modbus/test_acromag.cmd:/home/modbus/IOCStart.cmd -v /home/controls/modbus:/home/modbus -p 5064:5064 -p 5065:5065 -p 5064:5064/udp -p 5065:5065/udp andrewwade/modbusepicsdocker 

Then whenever you want to stop, run:

> sudo docker stop tcslabioc

or to restart run

>sudo docker restart tcslabioc. 

So if you update the .cmd or .db files just run the restart command above and the channels should automatically update when it reboots. For other cleanup and control commands see docker documentation.  It can also be configured to keep alive on system reboot.

The cmd and db files are included below in the attachments for reference. 

 

Quote:
  • Thermcouple reader is plugged into an Acromag ADC (10.0.1.55)
  • acromag1 is now reading this in:
    • ~/modbus/iocBoot/iocTest/test_acromag.cmd (contains ip address of ADC)
    • ~/modbus/db/TEMPMONCHANS.db (contains the EPICS channel definitions and calibration of thermocouple reader)
  • C4:AWC-TEMPMON_C (output channel)

Restored work done in http://nodus.ligo.caltech.edu:8080/TCS_Lab/201

 

 

 

 

Attachment 1: TCSIOCFILS.tar.gz
  229   Mon Jun 17 20:29:34 2019 JonLab InfrastructureComputingServer rack cleaned up, new workstation installed

In anticipation of the point absorber SURF project, I cleaned up the server rack and installed a new workstation today.

The workstation replaces the old one, whose hard drive had failed, with a more powerful machine. The hostname (tcs-ws), IP address (10.0.1.168), user name (controls), and standard password (written in the secret place) are all the same as before.

I moved the control consol from its old spot in the back corner of the lab to the bench beside the rack. This is a more convenient location because the Hartmann sensor realtime GUIs can now be easily seen from the optical tables. I mounted the HWS machine in the rack as well and reconnected the video multiplexer to all the machines.

I tested the Hartmann sensor Python software and confirmed it to be working. It required a minor bug fix to the realtime gradient field GUI code. It seems that since this script was last run, the input data file type has switched from pickled numpy to HDF5.

Attachment 1: IMG_3419.jpg
IMG_3419.jpg
  231   Mon Jul 22 09:44:21 2019 JonLab InfrastructureComputingInstalled Amplifying VGA Splitter

The VGA signal outputted by the multiplexer is too weak to drive two monitors. This has required video cables to be manually switched back and forth between the monitor mounted above the laser table and the desktop console.

Today I solved this problem by installing an amplifying (active) VGA splitter on the video output of the multiplexer. One output of the amplifier goes to the desktop monitor and the other to the laser table. We can now monitor the HWS realtime GUIs directly above the optical setup, with no cable swapping.

Attachment 1: IMG_3522.jpg
IMG_3522.jpg
Attachment 2: IMG_3421.jpg
IMG_3421.jpg
  238   Tue Aug 6 19:22:28 2019 JonElectronicsComputingQIL NFS server set up

I've started building the NFS server for the QIL cymac. It's sitting on the workbench in the TCS lab next to the rack. Please don't move it or any of the parts behind it.

  187   Thu Jul 13 10:11:57 2017 awadeElectronicsBorrowedBorrowed newport TrueRMS Supermeter

I lent your fancy Newport TrueRMS Supermeter with the thermocouple plugs on the top to the SURF student Jordon.  He has it in the cryo lab or the EE workshop with one of the PSL lab temperature probes.

Attachment 1: 2017-07-13_10.06.28.jpg
2017-07-13_10.06.28.jpg
Attachment 2: 2017-07-13_10.06.29.jpg
2017-07-13_10.06.29.jpg
ELOG V3.1.3-