  34   Thu May 6 21:32:26 2010 Won KimComputingHartmann sensorPeak detection and centroiding code 
 
 detect_peaks_uml.m 
  35   Tue May 11 10:32:00 2010 AidanComputingHartmann sensorPeak detection and centroiding code - reviewThis looks really efficient! However, I
think there's a systematic error in the calculation.
I tested it on some simulated data and it
 test_centroid_code.m 
  36   Thu May 13 16:54:46 2010 AidanComputingHartmann sensorRunning MATLAB programs in C on CentOS - only use R2008b for less hassle After much effort trying to get a
MATLAB routine to compile in C I discovered
the following pieces of information.
  
  39   Thu May 20 08:20:54 2010 AidanComputingHartmann sensorCentroiding algorithm and code to generate simulated data Here's a copy of an email I distributed
today that describes the centroid and simulation
code I wrote.
 test_spot_generation_and_centroiding.mgenerate_simulated_spots.mcentroid_image.m 
  42   Mon May 24 19:17:32 2010 AidanLaserHartmann sensorReplaced Brass Plate with Invar Hartmann PlateI just replaced the brass Hartmann plate
with the Invar one. The camera was off during
the process but has been turned on again.
  
  44   Wed May 26 14:58:04 2010 AidanMiscHartmann sensorHartmann sensor cooling fins added14:55 -  Mindy stopped by with the
copper heater spreaders and the cooling fins
for the Hartmann sensor. We've set them all
 HWS_CONFIG1.jpg 
  45   Thu May 27 08:25:37 2010 AidanElectronicsHartmann sensorHartmann sensor cooling fins added - base piece removed 8:10AM - I removed the base plate
from the Hartmann sensor. I want to know
what steady-state temperature the HWS achieves
 HWS_CONFIG2.jpg 
  46   Thu May 27 13:18:51 2010 AidanElectronicsHartmann sensorRemoved Cooling fins from Hartmann sensorI removed the cooling fins from the Hartmann
sensor to see what steady-state temperature
it reached without any passive cooling elements.
 HWS_CONFIG3.jpg 
  47   Thu May 27 15:42:06 2010 AidanElectronicsHartmann sensorHartmann sensor with just the base pieceI switched in just the base piece of the
Hartmann sensor. The cooling fins are removed.
I bolted the camera securely to the base
 HWS_CONFIG4.jpg 
  48   Thu May 27 17:49:02 2010 AidanElectronicsHartmann sensorHartmann sensor cooling fins added - base piece added Back to Configuration 1 again - this
time the fins were bolted very securely to
the camera.
 HWS_CONFIG1-tight.jpg 
  49   Tue Jun 15 16:30:10 2010 Peter VeitchMiscHartmann sensorSpot displacement maps - temperate sensitivity testsResults of initial measurement of temperature
sensitivity of Hartmann sensor
"Cold" images were taken
 spot_displacements_same_temp_0611.jpgspot_displacements_diff_temp_0611.jpg 
  50   Wed Jun 16 11:47:11 2010 AidanMiscHartmann sensorSpot displacement maps - temperate sensitivity tests - PRISMI think that the second plot is just showing
PRISM and converting it to its radial components.
This is due to the fact that the sign of
 Prism_as_radial_vector.pdf 
  51   Thu Jun 17 07:40:07 2010 James KMiscHartmann sensorSURF Log -- Day 1, Getting Started For Wednesday, June 16:   
  52   Thu Jun 17 22:03:51 2010 James KMiscHartmann sensorSURF Log -- Day 2, Getting StartedFor Thursday, June 17:
Today I attended a basic laser safety
training orientation, the second Introduction
  
  53   Sat Jun 19 17:31:46 2010 James KMiscHartmann sensorSURF Log -- Day 3, Initial Image Analysis   7x 
  54   Tue Jun 22 00:21:47 2010 James KMiscHartmann sensorSurf Log -- Day 4, Hartmann Spot Flickering Investigation I started out
the day by taking some images from the CCD
 7x 
  55   Tue Jun 22 22:30:24 2010 James KMiscHartmann sensorSURF Log -- Day 5, more Hartmann image preliminary analysis Today I spoke with Dr. Brooks and
got a rough outline of what my experiment
for the next few weeks will entail. I'll
 13x 
  56   Wed Jun 23 06:49:48 2010 AidanMiscHartmann sensorSURF Log -- Day 5, more Hartmann image preliminary analysisNice work!
 

  
  57   Wed Jun 23 22:57:22 2010 James KMiscHartmann sensorSURF Log -- Day 6, Centroiding So in addition to taking steps towards
starting to set stuff up for the experiment
in the lab, I spent a good deal of the day
 10x 
  58   Fri Jun 25 00:11:13 2010 James KMiscHartmann sensorSURF Log -- Day 7, SLED Beam Characterization 
 BeamData.xlsxbeam_pdfs.zipbeamdata.mgsbeam.m 
  61   Wed Jun 30 00:00:13 2010 Kathryn and WonComputingHartmann sensorrms of centroid position changesGiven
below is a brief overview of calculating
rms of spot position changes to test the
 rms_plot_shuffle.jpgrms_plot_shuffle.jpgrms_plot_noshuffle.jpgeLOG.zip 
  62   Thu Jul 1 09:40:13 2010 James KunertMiscHartmann sensorSURF Log 8 -- more SLED characterizationAs I started setting up my next experiment,
I noticed that the beam size from the SLED
appeared to be larger than expected from
 8x 
  63   Sun Jul 4 06:45:50 2010 Kathryn and WonComputingHartmann sensoranalyzing the wavefront aberrationHappy
Fourth of July!
 eLOG.zipwf_aberration_plot_hightemp_byintegration.jpgwf_aberration_plot_hightemp_fitted.jpg 
  64   Tue Jul 6 21:57:19 2010 James KunertMiscHartmann sensorSURF Log -- SLED fiber output temporal analysisIn the previous log, I describe the direct
measurement of the fiber output beam using
the Hartmann sensor with the plate removed.
 6x 
  65   Thu Jul 15 20:06:37 2010 James KMiscHartmann sensorSURF Log: Thermally Induced Defocus ExperimentsA quick write-up on recent work can be
found at: Google
Docs
 pydefoc.mpyanalyze.mpyimportsingle.mpyimportM.mframesumexport2.py 
  69   Thu Jul 22 21:46:55 2010 James KunertMiscHartmann sensorHartmann Sensor Thermal Defocus Measurement Noise & Ambient Light EffectsAs discussed during the teleconference,
a series of experiments have been conducted
which attempt to measure the thermally induced
 72210b_ambient.png 
  70   Fri Jul 23 10:33:08 2010 AidanComputingHartmann sensorDalsa camera ADC 8th digitizer error I plotted a histogram of the total intensity
of the Hartmann sensor when illuminated and
found that the 128 count problem extends
 histogram_of_dalsa_intensity.pdf 
  71   Fri Jul 23 12:33:51 2010 AidanComputingHartmann sensorInvar clamp scatterI illuminated the Hartmann sensor with
the output of a fiber placed ~1m away.
I noticed that the illumination was
  
  72   Fri Jul 23 12:38:58 2010 AidanComputingHartmann sensorImages for DalsaAttached are the background and 80% illumination
(~uniform spatially uniform) images that
Dalsa requested. 
 dark_0000.jpgbright_0000.jpg 
  73   Fri Jul 23 19:52:49 2010 AidanComputingHartmann sensorDalsa camera ADC 8th digitizer error I've attached an image that shows the locations
of those pixels that record a number of counts
= (2*n-1)*128. 
 image-location-of-excess_pixel_count_pixels.jpg 
  74   Sat Jul 24 10:50:14 2010 AidanElectronicsHartmann sensorLab Temperature and HWS temperature: pre-indium Hour-long trend puts the lab temperature
at 19.51C
Dalsa temperature:
  
  77   Mon Jul 26 12:17:25 2010 AidanElectronicsHartmann sensorAdded Indium to HWS I added some 0.004" thick indium
sheet to the copper heat spreaders and and
the heat sinks on the side of the HWS to
 indium-01.jpgindium-03.jpgindium-05.jpgindium-02.jpgindium-04.jpg 
  78   Mon Jul 26 18:47:12 2010 James KMiscHartmann sensorHex Grid Analysis Errors and Thermal Defocus NoiseMy previous eLog details how the noise
in Hartmann Sensor defocus measurements appears
to vary with ambient light. New troubleshooting
 centerror.PNGcentinit.pnghexgrid.png72010a.png72010a_nohex.PNG 
  82   Fri Jul 30 10:04:54 2010 AidanComputingHartmann sensorRestarted the HWS EPICS channels Restarted the HWS EPICS channels
on hartmann with the following
command:
  
  83   Fri Jul 30 11:01:31 2010 AidanComputingHartmann sensorEPICS softIoc alias I added an alias HWSIoc to
controls which can be used to
start the HWS EPICS softIoc.
  
  84   Fri Jul 30 13:38:39 2010 James KunertComputingHartmann sensorSummary of Thermal Defocus Data AnalysisBelow is a table summarizing the results
of recent thermal defocus experiments. The
values are the calculated change in measured
 ThermDefocMasterFunctions.pngThermDefoc--py4plot.png 
  88   Wed Aug 4 09:57:38 2010 Aidan, JamesComputingHartmann sensorRMS measurements with Hartmann sensor[INCOMPLETE
ENTRY]
We set up the Hartmann sensor and
 rms_analyze_centroids_aidan.pdfRMS_WonCode.pngRMS_WonCodeLessPrism.png 
  92   Wed Aug 18 18:38:11 2010 AidanComputingHartmann sensorHartmann sensor code I downloaded and tested revision
47 of the Adelaide Hartmann sensor code from
the SVN (https://trac.ligo.caltech.edu/Hartmann_Sensor/browser/users/won/HS_OO?rev=47).
 test_HS_Classes.mHS_Image.mHS_Centroids.mHWS_code_output.pngHWS_input_image.png 
  94   Mon Sep 13 18:24:52 2010 AidanLaserHartmann sensorEnclosure for the HWSI've assembled the box Mindy ordered from
Newport that will house the Hartmann sensor.
It's mainly to reduce ambient light, air
 00001.jpg00002.jpg00003.jpg00005.jpg 
  95   Tue Sep 28 10:41:32 2010 AidanLaserHartmann sensorAligning HWS cross-sample experiment - polarization issuesI'm in the process of aligning the cross-sampling
experiment for the HWS. I've put the 1"
PBS cube into the beam from the fiber-coupled
  
  96   Tue Sep 28 17:53:40 2010 AidanLaserHartmann sensorCrude alignment of cross-sampling measurementI've set up a crude alignment of the cross-sampling
system (optical layout to come). This was
just a sanity check to make sure that the
 2010_09_28-HWS_cross_sample_expt_crude_alignment_01.pdf 
  97   Wed Sep 29 16:49:36 2010 AidanLaserHartmann sensorCross-sampling experiment power budgetI've been setting up the cross-sampling
test of the Hartmann sensor, Right now I'm
waiting on a 50/50 BS so I'm improvising
 00001.jpg 
  98   Mon Oct 4 19:44:03 2010 AidanLaserHartmann sensorCross-sampling experiment - two beams on HWSI've set up the HWS with the probe beam
sampling two optics in a Michelson configuration
(source = SLED, beamsplitter = PBS cube).
 test001_two_beams_on_HWS.pdf 
  99   Tue Oct 5 12:51:16 2010 AidanLaserHartmann sensorVariable power in two beams of cross-sampling experimentThe SLED in the cross-sampling experiment
produces unpolarized light at 980nm. So I
added a PBS after the output and then a HWP
 test002_two_beams_on_HWS_analyze.pdfHartmann_Enclosure_Diagram__x-sampling.png 
  100   Thu Nov 4 13:31:19 2010 Won KimComputingHartmann sensorFrame Grabber SDK installation Appended
below is the step by step procedure that
  
  101   Tue Nov 23 06:15:08 2010 WonComputingHartmann sensorImage folder structureAttached below is a diagram that describes
the organisation of image folders that I
am using at the moment with Run_initialize
 image_folders.png 
  109   Wed Feb 23 20:18:30 2011 AidanElectronicsHartmann sensorSuccessfully re-started the Hartmann sensor I reattached the Hartmann Sensor
to the LENOVO machine that is running Ubuntu
and turned it on (it's been disconnected
  
  113   Thu Feb 24 14:23:58 2011 AidanLab InfrastructureHartmann sensorHartmann Sensor box cut down to size I reduced the height of the Hartmann
sensor box. This is what it looks like now:
 
 P1000109.jpgP1000110.jpgP1000111.jpgP1000113.jpg 
  114   Mon Feb 28 17:33:07 2011 AidanComputingHartmann sensorHartmann Seidel abberation channels in frame builderUsing the same methods as before, see below,
I've added some Hartmann sensor EPICS channels
to the frames.
  
  115   Mon Feb 28 17:56:32 2011 AidanComputingHartmann sensorGot HWS code running and interface to EPICSHere are the notes from today's efforts:
 
 
  