40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
TCS elog, Page 2 of 6
Not logged in
List
|
Find
|
Login
|
Help
New entries since:
Wed Dec 31 16:00:00 1969
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Type --
Laser
Lab Infrastructure
Things to Buy
Electronics
Computing
Misc
256 Entries
Goto page
Previous
1
, 2,
3
,
4
,
5
,
6
Next
ID
Date
Author
Type
Category
Subject
Text
115
Mon Feb 28 17:56:32 2011
Aidan
Computing
Hartmann sensor
Got HWS code running and interface to EPICS
Here are the notes from today's efforts:
120
Thu Mar 3 07:30:18 2011
Won
Computing
Hartmann sensor
Effect of high pixel count on rms
We have been investigating how pixel count
is related to the centroid displacements
by taking several sets of image frames with
11x
121
Tue Mar 8 11:30:26 2011
Aidan
Computing
Hartmann sensor
Hartmann sensor code changes and NTP server
I've made the following changes to the
Hartmann sensor code and to the machine running
the HWS.
122
Tue Mar 8 18:28:14 2011
Aidan
Computing
General
TO DO notes
Write a Wiki page that describes
how to add channels to the Athena Box
Write a Wiki page that describes how
123
Tue Mar 8 18:48:00 2011
Aidan
Computing
Hartmann sensor
HWS code is running and recording centroids
The Hartmann sensor is running continuously
and is now recording data to file. The formatting
has changed slightly with the data now stored
125
Wed Mar 9 01:00:12 2011
Peter Veitch, Won Kim
Computing
Hartmann sensor
Control of frame rate usign external trigger
We managed to successfully apply frame
rate control via external trigger from a
pulse generator.
131
Fri Apr 1 02:41:55 2011
Won
Computing
Hartmann sensor
exposure time and reproducibility of centroids
Here is a brief and preliminary summary
of rms of centroid displacements calculated
at a number of different exposure time values.
9x
132
Fri Apr 1 09:51:45 2011
Aidan
Computing
Hartmann sensor
Prism measurement
I analyzed the results from the prism
experiment. The time series and spectra of
the prism are attached.
134
Tue Apr 12 22:30:59 2011
Aidan
Computing
EPICS
Installed the thermistor on the Hartmann plate/created MEDM ADC Input screen
I restarted the Athena box and created
an MEDM screen that shows the 8 differential
input voltages next to their corresponding
135
Tue Apr 12 22:46:27 2011
Aidan
Computing
EPICS
Added temperature sensor channels to the frame builder and restarted fb1
Added the following to the frame builder
in /cvs/cds/caltech/chans/daq/C4HWS.ini
and restarted daqd as per instructions
138
Mon Apr 18 15:03:49 2011
Aidan
Computing
DAQ
Athena DAC channels hooked up to BNC patch panel
I added the four Athena DAC channels
to the second BNC patch panel in the rack.
At the moment there are only two EPICS channels
140
Fri Apr 22 19:51:37 2011
Aidan
Computing
EPICS
pyepics installed on princess_sparkle
I installed the pyepics
package on princess_sparkle since this is
much easier under Ubuntu than under CentOS.
141
Sun Apr 24 18:31:18 2011
Aidan
Computing
Network architecture
Added hosts and network drives on TCS machines
Under
edit ...
I added the names of the network
142
Mon Apr 25 16:28:27 2011
Aidan, Joe
Computing
Network architecture
Fixed problem network drive fb1:/cvs on Ubuntu & CentOS machines
With Joe's help we fixed the failure of
princess_sparkle to mount the
fb1:/cvs directory when relying
144
Tue May 10 00:55:08 2011
Won
Computing
Hartmann sensor
Matlab Compiler and Matlab Compiler Runtime
I have spent some time with Matlab
Compiler and Matlab Compiler Runtime (MCR).
145
Wed May 11 09:07:03 2011
Aidan
Computing
Hartmann sensor
Changed ownership of /opt/EDTpdv
I changed the ownership of /opt/EDTpdv
to controls with the command:
controls@princess_sparkle:/opt/EDTpdv$
146
Wed May 11 18:38:47 2011
Aidan
Computing
Hartmann sensor
test_HS binary
From Won: (the zip file is also on
the SVN /users/won/compiled_code/test_HS.zip)
147
Wed May 11 18:44:54 2011
Aidan
Computing
Hartmann sensor
Matlab Compiler and Matlab Compiler Runtime
Installing MCR
I located the MCRInstaller on our
distribution of MATLAB on the Ubuntu machine
148
Tue May 17 16:08:02 2011
Aidan
Computing
Hartmann sensor
Write speed of the frame grabber to file
The attached file shows the output
of the command. The maximum average frame
rate is 57.2Hz when the nominal frame rate
149
Wed May 18 18:52:12 2011
Aidan
Computing
Hartmann sensor
Test of position modulation algorithm
I measured the prism and displacement
of the Gaussian beam on the Hartmann sensor.
The beam pointing was modulated at 10mHz
154
Fri Sep 2 14:41:48 2011
Aidan
Computing
Hartmann sensor
QFLD-950-3S long term test finished
I ran a test of the HWS with the QFLD-950-3S
for 5 days. The test was terminated as we
need to disconnect all the cabling and tidy
181
Mon May 13 14:09:02 2013
Zach
Computing
DAQ
C2ATF model rebuilt
ATF:1812
182
Thu Dec 15 14:02:01 2016
Aidan
Computing
Network architecture
Correct network settings for Ubuntu 14 in /etc/network/interfaces
These settings work to get a computer onto
the TCS/ATF network.
183
Fri Dec 16 10:41:33 2016
Aidan
Computing
Network architecture
Correct network settings for Ubuntu 14 in /etc/network/interfaces
Spelt out in a searchable fashion:
auto <portname>
iface <portname> inet
189
Wed Oct 11 19:14:16 2017
Jon Richardson
Computing
Electronics
Replaced TCS Monitor
I replaced the dead 24" monitor on
the work bench, which is connected to the
video multiplexer. Mike Pedraza was
192
Fri Oct 13 18:35:29 2017
Jon Richardson
Computing
Electronics
Installed Maku Ethernet CCD Camera
I installed the Maku Gigabit CCD camera
driver software on the hws-ws machine. The
camera viewer can be opened from the terminal
194
Tue Oct 24 10:19:53 2017
Jon Richardson
Computing
Electronics
Installed Maku Ethernet CCD Camera
There is an SDK for the camera with compiled
examples. For a really quick image grab from
the command line, use the following:
195
Tue Oct 24 15:05:57 2017
Jon Richardson
Computing
Electronics
Installed a Realtime Beam Profiler for the Mako CCD Camera
Aidan found a C demo code for acquiring
a single image from the Mako CCD camera and
saving it to disk (SynchronousGrab -- aliased
196
Wed Oct 25 15:34:14 2017
Jon Richardson
Computing
Frame Grabber
Mako CCD Camera Code is Fixed
I fixed a bug in how the raw Mako CCD camera
images are being read into memory. The bmp
files turn out to have a block memory layout
197
Thu Oct 26 10:21:28 2017
Aidan
Computing
Beam size EPICS channels added to TCS-WS softIoc
I've added a softIoc to TCS-WS to capture
the beam size from the MAKO camera. The IOC
is run using ...
198
Thu Oct 26 10:31:31 2017
Aidan
Computing
DAQ
Beam size EPICS channels added to TCS-WS softIoc
These are also being written to frames
on FB4.
199
Thu Oct 26 10:45:44 2017
Aidan
Computing
DAQ
Beam size EPICS channels added to TCS-WS softIoc
See attached photo for how data is written
to frames ...
201
Tue Oct 31 14:37:49 2017
Aidan
Computing
DAQ
New Acromag units for AWC experiments - XT1221 ans XT1541
I set up an Acromag DAC today with the
fixed IP address 10.0.1.56. Last Friday Andrew
and Antonio set up an ADC unit with fixed
202
Thu Nov 9 14:18:56 2017
Aidan
Computing
DAQ
FB4 ip address has changed
We've had trouble logging into FB4.
I access the computer directly in the AWC
lab and found that the IP address had changed
203
Tue Nov 14 19:08:00 2017
Jon Richardson
Computing
Network architecture
Rsync Server for Automatic LDAS Backups
I implemented an access point for LDAS
to pull data from the TCS lab EPICS frame
archive (fb4:/frames) via rsync. The setup
206
Mon Feb 5 15:08:06 2018
Aidan
Computing
DAQ
Frame builder clock is totally wrong
The framebuilder on FB4 thinks the current
time is 26-Jan-2018 6:18AM UTC. The date
command on FB4 yields the correct date and
212
Wed May 30 18:50:05 2018
awade
Computing
DAQ
Rebooted fb4
Time was still off by nine days as of yesterday.
I tried rebooting remotely to see if time
would correct to system clock. It didn't
213
Wed May 30 18:59:49 2018
awade
Computing
DAQ
FB4 ip address has changed
Maybe you've resolved this now. I moved
the DHCP allocation to 10.0.1.160 and
above around that time because a bunch of
221
Thu Aug 16 11:52:27 2018
Aidan
Computing
DAQ
Added AWC thermocouple reader back to acromag1
Thermcouple reader is plugged into
an Acromag ADC (10.0.1.55)
acromag1
is now reading this in:
~/modbus/iocBoot/iocTest/test_acromag.cmd
222
Wed Oct 17 16:17:45 2018
awade, Aidan
Computing
DAQ
Added AWC thermocouple reader back to acromag1
Acromag IOC process was removed from PSL
lab acromag1 computer a few months ago.
Aidan needs them again but it would be better
224
Tue Dec 4 16:57:08 2018
Aidan
Computing
Hartmann sensor
Updated GIT version of HWS code
I changed the HWS code to the new git.ligo
HWS version.
Object files are in ~/hws
scripts
7
Thu Feb 4 14:05:59 2010
Aidan
Electronics
Ring Heater
Ring heater transfer function measurement 240mHz-5Hz
I've been trying to measure the ring heater
transfer function (current to emitted power)
by sweeping the supply voltage and measuring
8
Thu Feb 4 15:26:37 2010
Aidan
Electronics
Ring Heater
Ring heater transfer function measurement 240mHz-5Hz
10
Fri Feb 5 12:42:19 2010
Steve
Electronics
Pre-amplifier
Changes to board
Test entry
11
Mon Feb 8 10:45:50 2010
Steve O'Connor
Electronics
Pre-amplifier
replace Pot with fixed Resistor
12
Mon Feb 8 17:44:38 2010
Aidan
Electronics
Pre-amplifier
replace Pot with fixed Resistor
14
Thu Feb 11 21:46:23 2010
Aidan
Electronics
Ring Heater
Ring heater time constant measurement - start time
After leaving the ring heater off for several
hours I turned on a 40V, 0.2A supply at a
gps time of 949 988 700
15
Fri Feb 12 11:39:28 2010
Aidan
Electronics
Ring Heater
Ring heater transfer function
I applied a step function to the silver
WATLOW heater and measured the response with
the photodiode. The power spectrum of the
16
Fri Feb 12 21:00:06 2010
Aidan
Electronics
Ring Heater
Ring heater step function response - time series
Hideously slow internet at airport is making
me write a brief entry. This is the times
series of the hesilver watlow heater radiative
18
Mon Apr 12 17:25:01 2010
Aidan
Electronics
Hartmann sensor
Fiber-Camera Link demonstration
I installed the EDT PCIe4 DV C-Link
frame grabber in a spare Windows XP PC and
connected the Dalsa 1M60 camera directly
Goto page
Previous
1
, 2,
3
,
4
,
5
,
6
Next
ELOG V3.1.3-