40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  TCS elog  Not logged in ELOG logo
Message ID: 37     Entry time: Mon May 17 19:41:13 2010
Author: Aidan 
Type: Computing 
Category: Frame Grabber 
Subject: C code that calls MATLAB engine and centroiding algorithms 

This is an amended version of simple_take.c.

 

The files below are all in the directory /opt/EDTpdv/hartmann/src

  1. simple_hartmann.c   - the C code to access the frame grabber, retrieve an image, load the MATLAB engine and pass the image to MATLAB for centroiding
  2. centroid_image.m  - the MATLAB routine that centroids the image
  3. get_defocus.m - the MATLAB function that determines the defocus in the centroids
  4. build_simple_hartmann.sh - a shell script I wrote that contains the compile and link options to build the thing correctly 
Attachment 1: simple_hartmann.c  13 kB  | Hide | Hide all | Show all
/**
 * @file
 * An example program to show usage of EDT PCI DV library to acquire and
 * optionally save single or multiple images from devices connected to EDT
 * high speed digital video interface such as the PCI DV C-Link or PCI DV
 * FOX / RCX.
 * 
 * Provided as a starting point example for adding digital video acquisition
 * to a user application.  Includes optimization strategies that take
 * advantage of the EDT ring buffer library subroutines for pipelining image
... 521 more lines ...
Attachment 2: centroid_image.m  3 kB  | Hide | Hide all | Show all
function centroids = centroid_image(image, centroids)
%
% This function centroids a supplied image. It returns a centroids structure
%
% 'centroids' structure
% --------------------
% centroids.image_background_level  - the background intensity of an image
%                                     with no illumination on it
%          .spot_radius             - the radius of a hartmann spot
%          .spot_threshold_level    - the minimum intensity of pixels used to
... 98 more lines ...
Attachment 3: get_defocus.m  2 kB  | Hide | Hide all | Show all
function defocus = get_defocus(centroids)
% 
% a function to extract the defocus of the gradient field
%
% 'centroids' structure
% --------------------
% centroids.image_background_level  - the background intensity of an image
%                                     with no illumination on it
%          .spot_radius             - the radius of a hartmann spot
%          .spot_threshold_level    - the minimum intensity of pixels used to
... 56 more lines ...
Attachment 4: build_simple_hartmann.sh  740 Bytes  | Show | Hide all | Show all
ELOG V3.1.3-