Yesterday, I installed CentOS 5.3 on the Gateway GT5482 machine that housed the EDT frame-grabber.

  1. I installed CentOS 5.3 with all the default options
  2. As recommended by the README.lnx_pkg_reqs, I tried and failed to install the "Development Tools", "Development Libraries" and the "X Software Development" using the Add/Remove Software.
  3. I copied the entire install CD to ~/fgdriver on the hard disk.
  4. Installed the following packages at the command line

> yum install gcc

> yum install make

> yum install tk

> yum install kernel

 

I tried to run ~/fgdriver/linux.go at this point to install the EDT driver, but the installation failed about halfway through with the message "problem making the driver module". An investigation revealed that this was the due to the failure of ~/fgdriver/linux/module/makefile. I tried running that makefile separately to build the driver module and it crashed with the message: Can't find /lib/modules/2.6.18-128.el5/source/include/linux/mm.h. I concluded that the kernel source code wasn't installed

  • Added "Development Libraries" with Add/Remove Software
  • Ran the following command lines

> yum install kernel-devel

> yum install kernel-xen-devel

 And then I followed the instructions at the link: http://wiki.centos.org/HowTos/I_need_the_Kernel_Source

from: > yum install rpm-build redhat-rpm-config unifdef

 to:  > rpm -i http://mirror.centos.org/centos/5/updates/SRPMS/kernel-2.6.18-164.15.1.el5.src.rpm 2>&1 | grep -v mockb

and at the latter point the rpm build  pissed and moaned that it couldn't find the file kernel-2.6.18-164.15.1.el5.src.rpm

However, some combination of the above must have worked. I rebooted the computer and logged in again as root. At this point the install script ~/fgdriver/linux.go ran from start to finish without complaining. A quick test of the resulting /opt/EDTpdv/camconfig and then /opt/EDTpdv/serial_cmd showed that I could access the Dalsa 1M60 camera through the frame grabber.

 

 

 

 

 

 