Entry  Sun Jun 23 14:39:28 2013, Giorgos Mamakoukas, DailyProgress, SUS, Finished 6 PCB Boards 6_PCB_Boards.jpg
Entry  Mon Jun 24 23:32:04 2013, Giorgos Mamakoukas, DailyProgress, SUS, Power PCB boards and design of the box Photo0446.jpg
Entry  Tue Jun 25 22:26:03 2013, Giorgos, DailyProgress, SUS, Rare Panel Design and Mechanical Set-up 1.jpg2.jpg
Entry  Wed Jun 26 22:58:44 2013, Giorgos, DailyProgress, SUS, Hall-effect sensors and transfer functions  High-pass_filter.png
Entry  Fri Jun 28 00:30:46 2013, Giorgos, DailyProgress, SUS, Hall-effect sensors circuits High-pass_filter.pngTransfer_function_of_Hall-effect_sensors_circuits.png
Entry  Fri Jun 28 16:54:02 2013, Giorgos, DailyProgress, SUS, Low-pass filtering, Current booster, and Design of the Box Panels Low-pass_filter_for_dewhitening.png
Entry  Wed Jul 3 00:01:51 2013, Giorgos, DailyProgress, SUS, DAC and ADC controllers 
Entry  Wed Jul 3 22:56:53 2013, Giorgos, DailyProgress, SUS, ADC/DAC controllers, Power Boards 
Entry  Tue Jul 9 01:24:56 2013, Giorgos, Summary, SUS, HE sensors test, arrangement, and offset & Strain Gauge arrangement Hall_Effect_Connections.pngStrain_Gauge_&_Motors_Connections.png
Entry  Tue Jul 9 18:13:29 2013, Giorgos, Summary, SUS, Strain Gauge Voltage Offset  
Entry  Thu Jul 11 01:01:30 2013, Giorgos, Summary, SUS, LED connections, Power Boards, and DC magnetic field boards 
Entry  Tue Jul 16 00:15:08 2013, Giorgos, DailyProgress, SUS, Digital Voltage Meters, Labeling and Rest DigMeter.eps
Entry  Tue Jul 16 22:37:22 2013, Giorgos, DailyProgress, SUS, HE & Coils Boxes: Labeling and Power Lines for Fit-through Boards fit_through_boards_for_coils_HE_and_SG.eps
Entry  Fri Jul 19 16:14:06 2013, Edward Taylor & Nic Smith, DailyProgress, SUS, Solid works Model cryostatassembbly.JPG
Entry  Mon Jul 22 18:26:30 2013, Ben, DailyProgress, SUS, Wiring Shadow Sensor Emitter 2013-07-22_17.58.47.jpg2013-07-22_17.59.10.jpg2013-07-22_18.00.49.jpg
Entry  Wed Jul 24 01:00:36 2013, Giorgos, DailyProgress, SUS, Finished 1st Stage - Installation of MatLab 
Entry  Wed Jul 24 22:10:08 2013, Giorgos, DailyProgress, SUS, Adjusting DC motors resistors, Bode Plots in Matlab and Test Components IMG_4507.JPGLow_Pass.pdfIMG_4502.JPG
Entry  Thu Jul 25 22:51:39 2013, Giorgos, DailyProgress, SUS, Computer Feedback (Integrator & Damping), Motors' Speed and ADC bits/voltage conversion Integral_and_Damping_Digital_Filtering_together.pngFinal_TF_of_Integral_and_damping.png
Entry  Mon Jul 29 14:22:04 2013, Giorgos, DailyProgress, SUS, ADC & DAC bits/volts conversion, HE output and saturation of Transfer Functions TF_10mV.pngTF_100mV.pngTF_500mV.pngTF_500mV.png
Entry  Tue Jul 30 09:20:18 2013, Giorgos, DailyProgress, SUS, HE output & DAC output/voltage follower IMG_4531.JPGSimulink_Draft_model.slx
    Reply  Tue Jul 30 11:14:16 2013, Koji, DailyProgress, SUS, HE output & DAC output/voltage follower 
Entry  Thu Aug 1 11:43:15 2013, Giorgos, DailyProgress, SUS, Sensing Matrix and Calibration 
    Reply  Thu Aug 1 11:50:02 2013, Koji, DailyProgress, SUS, HE output & DAC output/voltage follower 
Entry  Sat Aug 3 14:50:51 2013, Giorgos, DailyProgress, SUS, Coupling from coil's signal Feedback_Loop.pdf
Entry  Sun Aug 4 22:44:36 2013, Giorgos, Summary, SUS, Volts to N conversion factors & Correction of Transfer Function Arrangement.pdfFeedback_Loop2.pdf
Entry  Tue Aug 6 09:27:43 2013, Giorgos, DailyProgress, SUS, Negation of Cross Coupling with Feedback 00.png
Entry  Thu Aug 8 11:32:00 2013, Giorgos, Summary, SUS, Compensation for Cross-Coupling and Vector Fitting CrossCoupling_AC1.bmpCrossCouplingofAC1_AfterCompensation.bmp
Entry  Fri Aug 9 08:43:37 2013, Giorgos, Summary, SUS, Simulink Model (1 DOF) - Step Response 1DOF_ACs_SimulinkModel.bmpStepResponseofACs.bmpStepResponseofACs.bmp
Entry  Mon Aug 12 07:59:58 2013, Giorgos, Summary, SUS, DAC and ADC saturation issues StepR.png
Entry  Tue Aug 13 21:09:44 2013, Giorgos, Summary, SUS, Overcoming Saturation: Feedback through DC Coils and Mu-metal Unshielded.bmpShielded_CrossCoupling.bmp
Entry  Tue Aug 13 22:49:45 2013, Giorgos, DailyProgress, SUS, Model of 3 DoF StepResponse_DC1in3d0fSimulinkmodel.bmpBodePlot_ADC1only_3DoF_Simulink_13Aug13.bmpADCinput_forDC1only_in3DOF_13Aug13.bmp
Entry  Wed Aug 14 00:05:00 2013, Giorgos, DailyProgress, SUS, 3DoF Stability in Simulink Maglev_3DoF_Giorgos.slxmag_lev_20130809Giorgos3Channels.mVector_Fitting_Cancellation.pngDC1toW_BodePlot.png
Entry  Thu Aug 15 23:19:36 2013, haixing, Noise Hunting, SUS, power spectrum and coherence of three hall effect sensors 10.png54.png
Entry  Fri Aug 16 18:37:56 2013, Giorgos, DailyProgress, SUS, Bringing Sensors closer to Plate, Correcting Offset and Gain 
Entry  Sat Aug 17 18:51:39 2013, Giorgos, DailyProgress, SUS, Noise Reduction when sensors are closer Noise.png
Entry  Fri Sep 6 15:47:40 2013, haixing, Summary, SUS, achieving stable levitation of the plate model_1DOF_v0.slxmodel_1DOF_script_v0.mdata_model_comparsion_1DOF.pngdata_model_comparsion_1DOF.pngsensor_signals.png
Entry  Fri Sep 6 17:07:39 2013, haixing, Summary, SUS, issues to be investigated  
Entry  Sun Sep 8 21:51:14 2013, haixing, Misc, SUS, issue of matlab function "margin()" with an unstable plant margins.pngnyquist.png
Entry  Thu Jul 8 16:41:29 2010, Jan, Misc, Seismometry, Ranger Pics 15x
Entry  Sat Jul 17 13:41:45 2010, Jan, Misc, Seismometry, Ranger  
Entry  Tue Jul 27 00:22:04 2010, Jan, Misc, Seismometry, Ranger 
Entry  Mon Aug 23 22:07:39 2010, Jenne, Things to Buy, Seismometry, Boxes for Seismometer Breakout Boxes 
Entry  Tue Dec 21 06:58:09 2010, rana, Things to Buy, Seismometry, Trillium Noise Plot Noise-TCompact.jpg
Entry  Wed Jan 19 17:13:11 2011, Jan, Computing, Seismometry, First steps towards full NN Wiener-filter simulator Coherence_Array.jpgTimeSeries_TM.jpgSeismicField.jpgCoh_Filt.jpg
Entry  Thu Jan 20 16:05:14 2011, Jan, Computing, Seismometry, Wiener v. seismometer 0 Performance_SNR1_A.jpgPerformance_SNR1_B.jpgPerformance_SNR10_A.jpgPerformance_SNR10_B.jpg
Entry  Fri Jan 21 12:43:17 2011, Jan, Computing, Seismometry, cleaned up code and new results TimeSeries_TM.jpgPerformance_SNR10_B.jpgPerformance_cNN_SNR10_B.jpg
Entry  Sat Jan 22 20:19:51 2011, Jan, Computing, Seismometry, Spatial spectra Map_3.jpgMap_4.jpgPerformance_cNN_SNR10_A.jpg
Entry  Sun Jan 23 09:03:43 2011, Jan, Computing, Seismometry, phase offset NN<->xi TimeSeries_fwd.jpgTimeSeries_bwd.jpg
Entry  Sun Jan 23 10:27:07 2011, Jan, Computing, Seismometry, spiral v. random 6x
Entry  Sun Jan 23 12:59:18 2011, Jan, Computing, Seismometry, Less seismometers, less subtraction? Performance_cNN_SNR10_B_N10_spiral.jpgPerformance_cNN_SNR10_B_N10_A2_spiral.jpgCoherence_spiral_A2.jpgPerformance_cNN_SNR10_B_N10_random.jpgPerformance_cNN_SNR10_B_N10_circ.jpg