40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  SUS Lab eLog  Not logged in ELOG logo
Entry  Wed Jul 7 13:05:07 2021, Paco, DailyProgress, 1418 nm AUX ECDL, New aspheric flexures 
    Reply  Fri Jul 9 11:40:42 2021, Paco, DailyProgress, 1418 nm AUX ECDL, New aspheric flexures IMG_1773.jpeg
       Reply  Wed Jul 14 12:21:08 2021, Paco, DailyProgress, 1418 nm AUX ECDL, ECDL lases... and MZ locked mid-fringe selfhomodyne_1418.jpg
          Reply  Wed Aug 4 11:36:30 2021, Radhika, DailyProgress, 1418 nm AUX ECDL, 1419 nm ECDL with 2um AOM tests rf_setup.jpgdiffraction_levels.png
             Reply  Tue Aug 10 09:51:44 2021, Paco, DailyProgress, 1418 nm AUX ECDL, 1419 nm ECDL AOM diffraction at 95 MHz rf_setup.jpg
                Reply  Thu Aug 12 11:49:59 2021, Radhika, DailyProgress, 1418 nm AUX ECDL, 1419 nm ECDL AOM diffraction at 95 MHz zeroth_order_contour.pdffirst_order_contour.pdf
                   Reply  Tue Aug 17 11:09:29 2021, rana, DailyProgress, 1418 nm AUX ECDL, 1419 nm ECDL AOM diffraction at 95 MHz 
                   Reply  Wed Sep 1 13:12:02 2021, Radhika, DailyProgress, 1418 nm AUX ECDL, 1419 nm ECDL AOM diffraction at 95 MHz 
Message ID: 1920     Entry time: Thu Aug 12 11:49:59 2021     In reply to: 1918     Reply to this: 1921   1922
Author: Radhika 
Type: DailyProgress 
Category: 1418 nm AUX ECDL 
Subject: 1419 nm ECDL AOM diffraction at 95 MHz 

[Paco, Radhika]

When previously trying to characterize the AOM, we had noticed no 1st order diffraction when operating at 80 MHz, but significant diffraction at 95 MHz. This motivated us to take measurements while sweeping across both RF drive frequency and Marconi drive power. For frequency, we swept from 80-120 MHz in steps of 1 MHz. For power, we swept across [3, 0, -3] dBm (3 dBm is max power before saturating AOM). We took our measurements of 0th and 1st order signal using an oscilloscope.

Contour plots of the 0th and 1st order signals can be seen in Attachments 1 and 2, respectively. Peak 1st order diffraction seems to occur at ~106 MHz. Using this AOM for a beat note measurement, the frequency difference would be greater than intended, which could lead to a weaker beat note signal. 

*Bonus: Today we moved the ECDL setup off the cryostat table and onto the other table. These measurements were taken after the move. 

Attachment 1: zeroth_order_contour.pdf  27 kB  Uploaded Thu Aug 12 12:58:08 2021  | Hide | Hide all | Show all
zeroth_order_contour.pdf
Attachment 2: first_order_contour.pdf  27 kB  Uploaded Thu Aug 12 12:58:19 2021  | Show | Hide all | Show all
ELOG V3.1.3-