Wed Nov 18 17:49:05 2020, Paco, DailyProgress, Optics, beam profiles 
|
Mon Dec 21 16:35:14 2020, Anchal, DailyProgress, Optics, Took beam profile of laser right off the head  
|
Tue Dec 22 15:54:03 2020, Anchal, DailyProgress, Optics, Took beam profile of near EOM area
|
Mon Dec 28 15:51:51 2020, Anchal, DailyProgress, Optics, Mode matching solution for Cavity
|
Thu Dec 31 16:41:59 2020, Anchal, DailyProgress, Optics, Mode matching solution for Cavity
|
Wed Jan 6 09:34:34 2021, Anchal, DailyProgress, Optics, Corrected analysis and found better solutions.
|
Fri Jan 8 17:00:26 2021, Anchal, DailyProgress, Optics, Included lens made by cavity input mirror and distrotion due to crystal
|
Fri Jan 8 17:17:19 2021, Anchal, DailyProgress, Optics, Included lens made by cavity input mirror and distrotion due to crystal
|
Tue Jan 26 11:33:32 2021, rana, DailyProgress, Optics, Included lens made by cavity input mirror and distrotion due to crystal
|
Tue Jan 26 11:34:51 2021, rana, DailyProgress, Optics, Included lens made by cavity input mirror and distrotion due to crystal
|
|
Message ID: 1886
Entry time: Thu Dec 31 16:41:59 2020
In reply to: 1884
Reply to this: 1887
|
Author: |
Anchal |
Type: |
DailyProgress |
Category: |
Optics |
Subject: |
Mode matching solution for Cavity |
|
|
Goals and restrictions:
- Use the fewest lenses as possible.
- The beam widths in both onward and reflection direction should be such that there is a 5-inch space somewhere where we can put in the faraday isolator which has an aperture size of 3 mm and intensity limit of 500 W/cm^2.
- The lens should not be closer than 1.5 inches from each other or to the EOM mount or cavity edge.
- Choose a lens from a list of focal lengths available in west bridge labs.
- Find the best overlap with the target beam of 18 um at the cavity waist with the most sensitivity with respect to lens positions.
Analysis & Results
Analysis and Data
Wed Jan 6 10:00:35 2021: This analysis was wrong. See SUS_Lab/1887. |
|