Author: Duo 
Type: HowTo 
Category:  
Subject: DAC Noise monitor PCB layers 

As per Chris's suggestions, I replaced the capacitors with surface mount ceramic capacitors, doubled the trace width to 0.5mm and adjusted the routings accordingly. New PCB layout is attached.

Attachment 1: NoiseMonitor.pdf  549 kB  Uploaded Wed Oct 24 16:03:47 2018  | Hide | Hide all
NoiseMonitor.pdf NoiseMonitor.pdf NoiseMonitor.pdf