Subject: Improved measurement of QE on photodiodes ~89% at 140K 

its worth looking into how fiber optic mode cleaning actually works:

https://doi.org/10.1201/9780203739662

In order to get a lot of cleaning you have to have a clean beam to begin with. There's a way to pre-clean by putting the laser output into a pinhole before coupling int othe single-mode fiber. Also, use a ~40-50m fiber to make sure the mod-mistanatched beam actually goes into the cladding rather than recombine into the Gaussian beam.