Entry  Mon Nov 25 21:46:56 2019, Koji, Summary, PD QE, System Diagram cryo_pd_test.pdfInAsSb_PD_mount_short.PDFPD_pin.pdf
    Reply  Wed Nov 27 20:38:57 2019, Koji, Summary, PD QE, System Diagram P_20191127_203612_vHDR_On.jpg
       Reply  Sun Dec 1 01:32:19 2019, Koji, Summary, PD QE, PD TEC cooling test 20191129191814_IMG_9146.JPGcooling_dark_current.pdf
          Reply  Tue Dec 3 15:32:39 2019, Koji, Summary, PD QE, PD TEC cooling test 
Message ID: 2460     Entry time: Mon Nov 25 21:46:56 2019     Reply to this: 2463
Author: Koji 
Type: Summary 
Category: PD QE 
Subject: System Diagram 

System diagram of the PD QE test with the IRLabs cryostat.

 

PT-SE (MS/PT-SE) connector data sheets

Connector/receptacles/tools https://www.peigenesis.com/images/content/pei_tabs/amphenol/pt-ptse-series/new-thumbs/123-146_pt_series.pdf
Amphenol catalog http://www.amphenol-industrial.com/images/catalogs/PT.pdf

Detoronics Hermeic Sealed Connectors (DT02H-18-*PN) http://www.hselectronics.com/pdf/Detoronics-Hermetic-Connectors.pdf

AF8 crimping tool (expensive!) https://www.mouser.com/ProductDetail/DMC-Tools/AF8?qs=gvhpkjpQEVSjrLbsepewjg%3D%3D
AF8 alternative https://www.jrdtools.com/?gclid=Cj0KCQiA2vjuBRCqARIsAJL5a-IQ9ztCEYKdo645v_RhUBJS3eMIars1LubjlKZoorS-lnx6ClDDiMUaAlZiEALw_wcB

 

Thermistor link: https://www.tec-microsystems.com//Download/Docs/Thermistors/TB04-222%205%25%20Thermistor_Specification_upd2018.pdf

TEC spec: Mounted TEC type: 2MD04-022-08/1 https://www.tec-microsystems.com/products/thermoelectric-coolers/2md04-series-thermoelectric-coolers.html
2MD04-022-08/1 dTmax = 96, Qmax = 0.4W, Imax = 0.7A,  Umax = 2.0, ACR = 2.29 Ohm

Attachment 1: cryo_pd_test.pdf  998 kB  Uploaded Fri Nov 29 16:15:30 2019  | Hide | Hide all
cryo_pd_test.pdf cryo_pd_test.pdf
Attachment 2: InAsSb_PD_mount_short.PDF  296 kB  Uploaded Fri Dec 6 12:56:43 2019  | Hide | Hide all
InAsSb_PD_mount_short.PDF
Attachment 3: PD_pin.pdf  143 kB  Uploaded Fri Dec 6 12:56:43 2019  | Hide | Hide all
PD_pin.pdf
ELOG V3.1.3-