40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Optical Contamination Facility elog, Page 1 of 1  Not logged in ELOG logo
Entry  Tue Feb 25 14:02:17 2020, Dennis, Progress, General, Optical Contamination Cavity Testing Queue 
Here is an update to the prioritized materials testing queue for UHV compatibility, which was last reported in elog:3


On-going test - can be terminated now: E1900220-v1: Optical
Entry  Tue Feb 19 09:35:33 2019, Dennis Coyne, Plan, General, OCF Queue 
Here is an update to the prioritized materials testing queue for UHV compatibility, which was last reported in elog:1


NKT Photonics large mode area, Photonic Crystal Fiber (PCF) ESM-12B
sourced from ThorLabs. This is a fiber under consideration for higher power, lower loss, green light injection for the OPO in the squeezer subsystem.
Entry  Thu Jan 17 16:04:17 2019, Dennis Coyne, General, General, revised thermoelastic response of the cavity mirror 
The original thermoelastic response of the mirror was documented in T970212, using the IDEAS finite element
code. The analysis was redone using ANSYS and an analytical (series expansion); These two approaches agree with each other fairly well. The new results
are similar to the original steady-state calculations in the original T970212-x0. The new results are uploaded to T970212-v1. While the  characteristic
Entry  Wed Jan 2 12:06:43 2019, Dennis Coyne, General, General, Current status/state of the Optical Contamination Facility (formerly OTF) 
The Optical Contamination Facility (formerly the OTF, Optical Test Facility) consists of 3 vacuum chambers with high-finesse, resonant optical
cavities used to test the effect of outgassing from materials/assemblies on optical properties (absorption, scatter @1064nm) over time.

basic description: P990032
ELOG V3.1.3-