40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
OMC elog, Page 1 of 9 |
Not logged in |
 |
|
New entries since: | Wed Dec 31 16:00:00 1969 | |
+
Thu Sep 27 20:19:15 2018, Aaron, Optics, General, Montecarlo simulation of the phase difference between P and S pols for a modeled HR mirror
| +
Thu Nov 1 19:57:32 2018, Aaron, Optics, General, Montecarlo simulation of the phase difference between P and S pols for a modeled HR mirror
| +
Thu May 16 12:41:28 2019, Chub, General, General, fire pillow found on optics table
|
Fri Jun 14 06:35:21 2013, Jeff, General, General, [LLO] L1 OMC status
| +
Thu Apr 18 20:47:54 2019, Joe, Optics, , OMC initial alignment and locking    
|
Fri Apr 19 09:35:28 2019, Joe, General, , Adjusting cavity axis, re-alignment of OMC and locking 
| +
Mon Apr 22 09:54:21 2019, Joe, General, , Shortening cavity (A5,A14,PZT11,PZT22) to get closer to design FSR 
|
Tue Apr 23 10:21:12 2019, Joe, Optics, Configuration, Moving the spots to the centre of the curved mirrors  
|
Wed Apr 24 13:58:51 2019, Joe, Optics, Characterization, OMC power budget and UV Epoxy Bonding of BS1
|
Thu Apr 25 15:05:19 2019, Joe, Optics, Characterization, Looking at PZT HOM spacing dependance and thinking about workflow
|
Fri Jun 15 15:45:49 2012, Koji, General, General, OMC Plan
|
Sat Jun 16 08:53:09 2012, Koji, General, General, To Do List
|
Wed Jun 20 00:10:53 2012, Koji, Facility, General, Hole on the wall was patched
|
Sat Jul 14 02:16:07 2012, Koji, General, General, Plan Update: July
|
Wed Jul 18 23:20:13 2012, Koji, Optics, Characterization, Mode scan results of ELIGO
| +
Mon Jul 23 17:15:14 2012, Koji, Clean, General, Talking with Margot
|
Tue Jul 24 11:41:29 2012, Koji, General, General, Useful references
|
Tue Jul 31 21:29:43 2012, Koji, General, General, Work completed in July [!]
|
Tue Jul 31 21:33:17 2012, Koji, General, General, Plan Update: August [!]
|
Wed Aug 1 19:35:00 2012, Koji, Facility, General, Floor cleaned / Workbench being built / Table top defect  
|
Sat Aug 11 00:59:14 2012, Koji, Facility, General, Laser Safety Barrier
|
Mon Aug 13 16:59:11 2012, Koji, Clean, General, Room Cleaning Log
|
Mon Aug 13 17:01:35 2012, Koji, Clean, General, Particle Counts
|
Tue Aug 14 03:29:06 2012, Koji, Supply, General, Clean supply rack 
|
Wed Aug 22 20:16:43 2012, Koji, Facility, General, Workbenches have been installed / Clean room stools 
| +
Tue Sep 25 14:18:14 2012, Koji, Clean, General, Particle Counts
| +
Mon Oct 1 16:06:55 2012, Koji, Clean, General, Particle Counts
|
Fri Oct 5 03:39:58 2012, Koji, Optics, General, RoC Test setup 
|
Mon Oct 8 11:30:47 2012, Koji, Optics, General, EG&G 2mm photodiode angle response
|
Tue Oct 9 04:59:24 2012, Koji, Optics, General, OMC Test Optical Setup 
|
Tue Oct 9 05:03:15 2012, Koji, Electronics, General, OMC Test Electronics Setup 
|
Fri Oct 12 17:15:19 2012, Koji, Optics, General, Loan from the 40m / ATF
|
Tue Oct 16 15:50:09 2012, Koji, General, General, Work completed in August/September [!]
|
Tue Oct 16 15:51:01 2012, Koji, General, General, Plan Update: October [!]
|
Wed Oct 17 20:36:04 2012, Koji, Optics, General, RoC test cavity locked  
| +
Thu Oct 18 20:23:33 2012, Koji, Optics, Characterization, Improved measurement 
|
Wed Nov 7 01:28:20 2012, Koji, Optics, Characterization, Wedge angle test (A1) 
|
Wed Nov 7 20:21:42 2012, Koji, General, General, Work completed in October [!]
|
Wed Nov 7 20:44:11 2012, Koji, General, General, Plan Update: November [!]
|
Thu Nov 8 13:24:53 2012, Koji, Optics, Characterization, More wedge measurement
|
Thu Nov 8 19:47:55 2012, Koji, Electronics, Configuration, Solder for PZTs
|
Thu Nov 8 19:52:57 2012, Koji, Optics, General, How to apply UV epoxy
|
Thu Nov 8 20:12:10 2012, Koji, Optics, Configuration, How many glass components we need for a plate
|
Fri Nov 9 00:43:32 2012, Koji, Optics, Characterization, Further more wedge measurement 
|
Sat Nov 17 02:31:34 2012, Koji, Optics, Characterization, Mirror T test
| +
Mon Nov 19 13:33:14 2012, Koji, Optics, Characterization, Resuming testing mirror RoCs
|
Mon Nov 26 01:40:00 2012, Koji, Optics, Characterization, More RoC measurement
|
Thu Nov 29 21:18:23 2012, Koji, Optics, General, OMC Mounting Prisms have come 
|
Tue Dec 18 20:04:40 2012, Koji, Optics, Characterization, Prism Thickness Measurement
| +
Wed Dec 19 18:47:03 2012, Koji, Clean, General, First Contact Training with Margot
|
|