402
Sat Nov 21 13:58:30 2020
Koji
Electronics
Characterization
Dark Current Measurement for InGaAs QPDs
Dark current measurement for InGaAs QPDs
(OSI FCI-InGaAs-Q3000) has been done using
Keithley 2450 and Frank's diode test
403
Sun Nov 22 13:49:12 2020
Koji
Electronics
Characterization
Impedance Measurement for InGaAs QPDs
To know any anomaly to the junction
capacitance of the QPD segments, the RF impedances
were tested with a hand-made impedance measurement.
404
Mon Nov 23 23:17:19 2020
Koji
Electronics
Characterization
The dark noise of the Q3000 QPDs
The dark noise levels of the four Q3000
QPDs were measured with FEMTO DLPCA200 low
noise transimpedance amp.
405
Tue Nov 24 10:45:07 2020
gautam
Electronics
Characterization
The dark noise of the Q3000 QPDs
I see that these measurements are done
out to 100 kHz - I guess there is no reason
to suspect anything at 55 MHz which is where
406
Tue Nov 24 12:27:18 2020
Koji
Electronics
Characterization
The dark noise of the Q3000 QPDs
The amplifier BW was 400kHz at the gain
of 1e7 V/A. And the max BW is 500kHz even
at a lower gain. I have to setup something
407
Fri Feb 5 07:40:37 2021
Stephen
Supply
General
OMC Unit 4 Build Machined Parts
OMC Unit 4 Build Machined Parts are currently
located in Stephen's office. See image
of large blue box from office, below.
408
Thu May 20 17:03:50 2021
Koji
General
General
SRS LCR meter SRS720 borrowed from Downs
Item loan: SRS LCR meter SRS720 borrowed
from Downs. The unit is at the 40m right
now for testing with an excelitas PD. Once
409
Sun May 30 15:17:16 2021
Koji
General
General
DCPD AF capacitance measirement
Attachment 1: System diagram.
The reverse bias voltage is controlled by
DS335. This can produce a voltage offset
410
Sun May 30 15:32:56 2021
Koji
General
General
DCPD AF capacitance measirement
Measurement result:
The capacitance at no bias was
460~500pF. This goes down to below 300pF
411
Wed Jul 7 14:21:50 2021
Stephen
Supply
General
OMC Unit 4 Build Machined Parts
More explicit insights into the inventory
for the Unit 4 build. Image of inventory
included below.
412
Thu Jun 23 21:03:33 2022
Koji
Facility
General
Moving the small optical table to CAML (TCS Lab)
I've cleared the small optical table
and wondered how to move it out of the room.
Fortunately, the north side of the big table
413
Tue Jun 28 16:13:34 2022
Koji
General
General
The small optical table not small enough to get out
The table width was an inch too large compared
to the door width. We need to tilt the table
and it seemed too much for us. Let's