  503   Tue Mar 7 23:00:16 2023 Thejas OpticsCharacterizationOMC Lab clean upToday, Koji and I cleaned up the the lab
space and made some space on the
optical table for radius of curvature measurement
 IMG_0173-2.jpgIMG_0175-2.jpg 
  504   Wed Mar 8 17:27:51 2023 Thejas OpticsCharacterizationA+ OMC Curvature minimum of curved optics [Stephen, Thejas]

Today, a more rigorous effort was
made to re-measure the position of the optics
 image.jpeg 
  505   Fri Mar 10 10:23:08 2023 ThejasOpticsCharacterizationA+ OMC curved mirror radius of curvature OMC test set-up

Yesterday, laser beam output from
the fibre follwoing teh mode-matching lenses
 IMG_1E4662B2100B-1.jpegScreenshot_2023-03-10_at_10.49.45.pngScreenshot_2023-03-10_at_10.51.42.pngOMC_8_(dragged).pdf 
  506   Fri Mar 10 11:12:57 2023 Thejas OpticsCharacterizationA+ OMC Curvature minimum of curved optics [GariLynn, Stephen, Thejas]

Yesterday, we placed an iris (borrowed
from OMC Lab) infront of the spherical transmission
  
  507   Tue Mar 14 10:41:06 2023 Thejas OpticsCharacterizationA+ OMC curved mirror characterization[Camille, GarriLynn, Stephen, Thejas]

Folllowing the replacement of the
spherical transmission / reference mirror
 image.jpeg 
  508   Tue Mar 14 12:12:41 2023 Koji OpticsCharacterizationA+ OMC curved mirror characterizationRoC: 2.65m ! Interesting. I'll wait
for the follow-up analysis/measurements.
The RoC may be dependent on the area (diameter)
  
  509   Tue Mar 14 18:24:03 2023 Thejas OpticsCharacterizationA+ OMC Curved mirror radius of curvatureToday, I tried to measure the radius of
curvature of the curved mirror using the
input beam for the OMC test set-up. It was
 Screenshot_2023-03-14_at_18.29.56.pngScreenshot_2023-03-14_at_18.32.32.pngScreenshot_2023-03-14_at_18.33.28.png 
  510   Tue Mar 14 20:06:03 2023 Koji OpticsCharacterizationA+ OMC Curved mirror radius of curvatureIf the mirror has the RoC, it works as
a lens. And you should be able to see the
effect in the beam profile.
  
  511   Wed Mar 15 15:28:24 2023 Thejas OpticsCharacterizationA+ OMC Curved mirror radius of curvatureThanks for teh comment Koji. Yes, I did
see this effect by comparing the beam sizes
with and without the curved mirror. But the
  
  512   Wed Mar 15 17:07:35 2023 Koji OpticsCharacterizationA+ OMC Curved mirror radius of curvatureI hope you can find useful lenses from
the lens kit in the cabinet. If you need
more lenses and mounts, talk to our students
  
  513   Fri Mar 17 15:01:21 2023 Koji OpticsCharacterizationA+ OMC Curved mirror radius of curvatureThanks Koji, the lenses available in the
cabinet in the lab actually sufficed. 

  
  514   Fri Mar 24 07:38:54 2023 Camille MakaremOptics ROC measurements of the curved mirrors[Thejas, Camille]
21 March 2023

We made slight adjustments to the
  
  515   Fri Mar 24 07:47:37 2023 Camille MakaremOptics ROC measurements of the curved mirrors[Camille]
22 March 2023
Beam profile measurements were continued
 CurvedMirror_FL_measurments.PNGsn07.PNG 
  516   Tue Mar 28 11:21:27 2023 Camille MakaremOptics Sagitta measurements of curved mirrors[Camille, Stephen, Thejas]

Curved mirror sn02 was used to test
 CurvedMirrorSN02_SurfaceProfiles.PNG 
ELOG V3.1.3-